{"product_id":"omron-zn-thx11-sa-thermo-humidity-logger","title":"Enregistreur thermo-humidité Omron ZN-THX11-SA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Omron ZN-THX11-SA is a dedicated station device engineered for industrial environmental monitoring and logging. It functions alongside an external sensor head to record and track atmospheric temperature and relative humidity parameters across critical production zones, cleanrooms, and warehouse storage locations. The device utilizes a front-panel digital display to provide immediate visual confirmation of localized parameters while running real-time processing calculations on the incoming sensor feedback. Collected records are stored locally in internal memory or written directly to removable solid-state storage media. Compatible with standard external power arrangements and secondary backup battery power options, it guarantees continuous data acquisition safety for delicate pharmaceutical, electronics, and food-processing applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeamless plug-and-play synchronization with specialized thermo-humidity sensor heads.\u003c\/li\u003e\n\u003cli\u003eDual-step 5-digit digital display for simultaneous parameter or status review.\u003c\/li\u003e\n\u003cli\u003eMulti-tier hardware measurement intervals ranging from seconds up to hourly tracking.\u003c\/li\u003e\n\u003cli\u003eDual operating modes enabling system optimization for active reporting or low-power storage tracking.\u003c\/li\u003e\n\u003cli\u003eRemovable memory card interface support for secure offline data backup and configuration deployment.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm output port infrastructure for direct linking to auxiliary warning devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSemiconductor production facilities and cleanroom climate verification.\u003c\/li\u003e\n\u003cli\u003ePharmaceutical distribution warehouses and climate-controlled storage areas.\u003c\/li\u003e\n\u003cli\u003eFood and beverage manufacturing facility temperature and humidity auditing.\u003c\/li\u003e\n\u003cli\u003eServer rooms and critical data center environmental management.\u003c\/li\u003e\n\u003cli\u003eCalibration laboratories and precision testing environment monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance and System Capacity\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eConnected Sensor Options\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eThermo-Humidity Sensor Head (ZN-THS@@-S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eDisplay System\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eLCD 7-segment 5-digit 2-step display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMeasurement Interval Settings\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e10 s, 20 s, 30 s, 1 min, 2 min, 5 min, 10 min, 20 min, 30 min, 1 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMathematical Functions\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eInstantaneous value, maximum value, minimum value, average value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eOperating Modes\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eNormal mode, sleep mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eInternal Storage Capacity\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eApprox. 8,500 data items\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eExternal Storage Options\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSD card (saves measured values; saves\/reads parameter adjustments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eRecommended External Media\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eOMRON HMC-SD291 SD Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eDC Source Input\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e24 VDC $\\pm$10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eAC Power Adapter Range\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e100 to 240 VAC \/ 50 to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eBattery Capacity Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e2 AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eBattery Lifespan Expectancy\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eApprox. 1 year (sleep mode, 10 min interval, 2 AAA NiMH batteries, SD card removed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eMain Unit Operating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eAmbient Operating Humidity\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e20% to 85% (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eNet Device Weight\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e0.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eGross Shipping Weight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eInterface Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSensor Terminal\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eDedicated Input Port\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eDirect docking connection for ZN-THS@@-S sensor head series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eAlarm Output\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eAlarm Output Connector\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eAuxiliary dry contact for trigger limits or warning alerts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eDC Input Port\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCircular DC Jack\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003ePower input connection via straight DC cable or AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eExternal Storage Slot\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eStandard SD Card Slot\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eRemovable media slot for logging files and loading profile updates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Setup:\u003c\/strong\u003e Position the logger unit away from surfaces subjected to severe vibration or mechanical shocks. Ensure the front panel remains clearly scannable for engineering personnel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief:\u003c\/strong\u003e Clip the included ferrite core onto the incoming DC lines near the connection jack to minimize electromagnetic interference (EMI\/RFI) on sensitive sensor readouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Routing:\u003c\/strong\u003e Keep the connection cable linking the logger base to the thermo-humidity sensor head separate from heavy power cables, motor switchboards, or high-current transmission lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e The station unit body is rated for up to 85% relative humidity; it must be shielded from direct fluid exposure, splashing water, or condensing atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Handling:\u003c\/strong\u003e When utilizing the device on battery-only mode, deploy nickel-metal hydride (NiMH) cells and set the device logic to sleep mode to sustain standard long-term sampling runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhich external probe is compatible with this environmental tracking base?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIt connects directly to the Omron Thermo-Humidity Sensor Head series designated as ZN-THS@@-S.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan the logging data be retrieved without interrupting live system power?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes, data files written to the removable SD card can be retrieved according to standard field maintenance protocols.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the maximum number of recording entries available within the built-in storage?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe integrated internal memory space can hold approximately 8,500 independent data points before requiring data extraction.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat type of SD card is recommended by the factory for standard applications?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe recommended factory part number for system verification is the OMRON HMC-SD291 solid-state media card.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow are the max, min, and average parameter metrics retrieved?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe mathematical function configuration lets you toggle through instantaneous values, maximums, minimums, and averages on the front LCD screen.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIs an external transformer or adapter packed alongside the main logging module?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe package includes a straight-type DC cable, alarm connector, instruction literature, and utility software disk. Direct AC adapter selection varies by regional requirements.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan this logger run continuously for months without line power access?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes, it can run for approximately 1 year on 2 AAA NiMH batteries when utilizing sleep mode settings with a 10-minute measurement interval and the SD card omitted.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat action should be taken if condensation forms within the sensing room?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe station operates strictly down to 20% and up to 85% relative humidity without condensation. If moisture builds up, isolate power and let the system dry entirely.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat information is displayed via the two-tier screen layout?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe 7-segment 5-digit dual display lets operators simultaneously review multi-variable logs such as temperature alongside humidity readouts.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow often does the station scan the environment for parameter updates?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe execution cycle is adjustable, providing engineering steps of 10s, 20s, 30s, 1 min, 2 min, 5 min, 10 min, 20 min, 30 min, up to 1 hour.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077919564139,"sku":"ZN-THX11-SA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Omron_ZN-THX11-SA_1.png?v=1779618315","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-zn-thx11-sa-thermo-humidity-logger","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}