{"product_id":"prosoft-mvi56e-mnetc-controllogix-modbus-tcp-ip-enhanced-module","title":"Module amélioré ProSoft ControlLogix Modbus TCP\/IP MVI56E-MNETC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETC (MVI56EMNETC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as an advanced Modbus TCP\/IP multi-client and server interface, engineered specifically for the Rockwell Automation ControlLogix platform. In mission-critical sectors such as oil refining, thermal power plants, and subsea mining, the module provides a high-speed data conduit between the processor and distributed Modbus TCP\/IP devices. Unlike standard modules, the \"Enhanced\" series offers improved backplane speed and a larger internal database, enabling the integration of hundreds of smart field instruments without compromising scan times. By delivering real-time diagnostics and support for multiple simultaneous connections, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces system troubleshooting time and eliminates communication bottlenecks that lead to costly production outages.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Model Variations\u003c\/h3\u003e\n\u003cp\u003eThe MVI56E series is designed with modularity to address different environmental stressors. Understanding the model suffix is critical for ensuring long-term hardware reliability in the field.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard (MVI56E-MNETC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for controlled industrial environments. It operates within a standard temperature range and features standard circuit board protection for general-purpose applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Temperature (MVI56E-MNETCXT):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for unconditioned cabinets or extreme geographic locations. This version extends the operating range from -25 to 70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"XT\" variant includes a factory-applied conformal coating. This protective layer shields the internal electronics from moisture, chemical corrosion, and conductive dust, which is essential for saltwater environments or chemical processing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMVI56E-MNETC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP (Client and Server)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA @ 5 VDC \/ 3 mA @ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp (Standard)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp (XT Version)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED Indicators (APP, OK) \/ Web Page Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCritical Technical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many Modbus Client connections can the MVI56E-MNETC support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" in the model name stands for Client. This module is enhanced to support up to 30 simultaneous Client connections, allowing it to aggregate data from a vast network of remote I\/O, drives, and power meters concurrently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the MVI56E-MNETC compatible with older ControlLogix L6 processors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module maintains downward compatibility with L6 series processors and older versions of RSLogix 5000, as well as the modern Studio 5000 environment. It fits into any standard 1756 ControlLogix chassis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the 'Enhanced' (E) series over legacy MVI56 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Enhanced series supports \"Discovery Service,\" allowing the ProSoft Configuration Builder software to find the module on the network without knowing its IP address. It also features a scrolling LED display for real-time status and error codes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical \u0026amp; Corrosive Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor installations located in wastewater treatment or heavy chemical plants, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETCXT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be specified. The conformal coating is vital to prevent \"silver migration\" and corrosion on the PCB traces caused by hydrogen sulfide (H2S) or high salinity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure maximum cybersecurity and deterministic performance, always use a managed industrial switch. Segregate the Modbus TCP\/IP traffic from the corporate IT network using VLANs to prevent broadcast storms from impacting the ControlLogix backplane performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen operating at the upper limit of the temperature range (60 deg C or 70 deg C for XT), ensure that the chassis power supply is not overloaded. High current draw on the 5 VDC backplane rail generates significant heat; maintain a minimum of 5 cm clearance around the chassis for adequate airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256555371,"sku":"MVI56E-MNETC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/mvi56e-mnetc-1v5rsrtaspl.png?v=1775727273","url":"https:\/\/www.plcprotech.com\/fr\/products\/prosoft-mvi56e-mnetc-controllogix-modbus-tcp-ip-enhanced-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}