{"product_id":"prosoft-mvi56e-mnetcr-modbus-tcp-ip-multi-client-enhanced-communication-module-for-remote-chassis","title":"MVI56E-MNETCR | ProSoft | Module de communication amélioré Modbus TCP\/IP multi-client","description":"\u003cp\u003eThe \u003cstrong\u003eMVI56E-MNETCR\u003c\/strong\u003e is a Modbus TCP\/IP Multi-Client Enhanced Communication Module for Remote Chassis that allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface with multiple Modbus TCP\/IP server-compatible instruments and devices. This communication module improves network data transfer performance when controlling multiple servers on a Modbus TCP\/IP network by supporting up to 30 clients. Operating as a single-slot module on the 1756 ControlLogix backplane, the \u003cstrong\u003eMVI56E-MNETCR\u003c\/strong\u003e uses a small I\/O data image for data transfer between the module and the ControlLogix processor, making it suitable for ControlNet or Ethernet remote rack installations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports up to 30 Clients with up to 16 commands for each client to enable multi-server connectivity\u003c\/li\u003e\n\u003cli\u003eIntegrated with RSLogix 5000 version 16 or higher using a supplied Add-On Instruction (AOI) or ladder file\u003c\/li\u003e\n\u003cli\u003eProgrammatically enables and disables commands easily from ladder logic to support multiple applications or recipes without reconfiguring the module\u003c\/li\u003e\n\u003cli\u003eRemotely configures and diagnoses problems through remote racks using EtherNet\/IP or ControlNet via interface modules without requiring RSLinx OEM software\u003c\/li\u003e\n\u003cli\u003eBuilt-in web server provides web-enabled Ethernet port access to on-board documentation, module status, and firmware updates\u003c\/li\u003e\n\u003cli\u003eBackward compatible with previous MVI56-MNETC applications by supporting existing ladder logic and configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed ControlLogix remote chassis architectures\u003c\/li\u003e\n\u003cli\u003eControlNet or Ethernet remote rack communication networks\u003c\/li\u003e\n\u003cli\u003eIndustrial multi-server server-client bridging applications\u003c\/li\u003e\n\u003cli\u003eSCADA and infrastructure remote monitoring networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct No.\u003c\/td\u003e\n\u003ctd\u003eMVI56E-MNETCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Multi-Client Enhanced Communication Module for Remote Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA @ 5 V DC, 3 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e30g Operational, 50g non-operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e5 g from 10 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eBattery Status (ERR), Application Status (APP), Module Status (OK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-Character LED Display\u003c\/td\u003e\n\u003ctd\u003eScrolling, Alpha-numeric, shows Module, Version, IP, Application Port Setting, Port Status, and Error Information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e10\/100 Base-T, RJ45 Connector, for CAT5 cable, Link and Activity LED indicators, Auto-crossover cable detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipped with Unit\u003c\/td\u003e\n\u003ctd\u003e5-foot Ethernet straight-through cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003eUser-definable module data memory mapping of up to 5000, 16-bit registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Function Codes Supported\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3, 4, 5, 6, 7, 15, and 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Tool\u003c\/td\u003e\n\u003ctd\u003eProSoft Configuration Builder (PCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Placement:\u003c\/strong\u003e After checking the placement of the jumpers, insert the module into the single-slot 1756 ControlLogix chassis. Use the standard technique recommended by Rockwell Automation to remove and install modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Precaution:\u003c\/strong\u003e When inserting or removing the module while backplane power is on, an electrical arc can occur. Ensure power is removed or the area is known to be non-hazardous before proceeding to avoid contact wear or unintended motion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Configuration:\u003c\/strong\u003e The Setup Jumper acts as write protection for the module flash memory. In write-protected mode, the Setup pins are not connected. If installing in a remote rack, leaving the Setup pins jumpered allows firmware updates without physical access but leaves the module open to unexpected updates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity Segmentation:\u003c\/strong\u003e Align with IEC 62443-1-1 and implement system segmentation (firewalls, DMZ, or unidirectional communication) to control data flow for security reasons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware and Logic:\u003c\/strong\u003e Before operation, import the required MVI56EMNETCR_AddOn_Rung_vXXX.L5X file containing the Add-On Instruction, user-defined data types, controller tags, and ladder logic into RSLogix 5000.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eANSI \/ ISA 12.12.01 Class I Division 2, GPs A, B, C, D\u003c\/li\u003e\n\u003cli\u003eCSA\/cUL C22.2 No. 213-M1987\u003c\/li\u003e\n\u003cli\u003eCSA CB Certified IEC61010\u003c\/li\u003e\n\u003cli\u003eATEX EN60079-0 Category 3, Zone 2\u003c\/li\u003e\n\u003cli\u003eATEX EN60079-15\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\/cUL\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256260459,"sku":"MVI56E-MNETCR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/mvi56e-mnetcr-f0gjrtqtnpz.jpg?v=1775727275","url":"https:\/\/www.plcprotech.com\/fr\/products\/prosoft-mvi56e-mnetcr-modbus-tcp-ip-multi-client-enhanced-communication-module-for-remote-chassis","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}