{"product_id":"prosoft-rlx2-ihnf-a-fast-industrial-hotspot-fcc-model","title":"ProSoft RLX2-IHNF-A Point d'accès industriel rapide modèle FCC  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for high-speed wireless connectivity in harsh industrial environments, the \u003cstrong\u003eProSoft RLX2-IHNF-A\u003c\/strong\u003e provides robust 802.11abgn Fast Industrial Hotspot capabilities under FCC regulatory frameworks. This high-reliability device is optimized for critical control networks requiring low-latency wireless bridging and client connectivity. Equipped with an extruded aluminum housing and dynamic network management capabilities, it ensures secure data transmission across complex industrial topologies.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiband Flexibility:\u003c\/strong\u003e Dual-band 802.11abgn support allows configuration on both 2.4 GHz and 5 GHz bands.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Network Management:\u003c\/strong\u003e Supports VLAN tagging for network segmentation, Quality of Service (QoS) for packet prioritization, and IGMP Snooping to optimize multicast traffic.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Enclosure:\u003c\/strong\u003e Housed in a heavy-duty extruded aluminum chassis designed for high vibration and harsh thermal conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Integration:\u003c\/strong\u003e Designed for standard 35mm DIN rail mounting, minimizing panel footprint.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eOil and Gas offshore and onshore production facilities requiring rugged wireless links.\u003c\/li\u003e\n  \u003cli\u003eWater and Wastewater SCADA networks for long-range, high-speed RTU communication.\u003c\/li\u003e\n  \u003cli\u003eMaterial Handling systems, including Automated Guided Vehicles (AGVs) requiring continuous roaming.\u003c\/li\u003e\n  \u003cli\u003eFactory Automation setups deploying decentralized wireless I\/O architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; width: 30%; text-align: left;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003eProSoft Technology\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003eRLX2-IHNF-A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003eWireless Standards\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003e802.11a, 802.11b, 802.11g, 802.11n\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003eFrequency Band\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003e2.412 GHz to 2.462 GHz (FCC Model)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003eRegulatory Domain\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003eFCC (Channels 1 to 11)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003eNetwork Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003eNAT, VLAN, QoS, IGMP Snooping\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003eEnclosure Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003eExtruded Aluminum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003eMounting Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003eDIN Rail\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003e1.1 lbs (499 g)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; text-align: left;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; text-align: left;\"\u003e210 x 150 x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The RLX2-IHNF-A is configured exclusively for the FCC regulatory domain. For European deployments, the ETSI-compliant RLX2-IHNF-E must be specified to satisfy local radio emission standards. Note that mixing FCC and ETSI hardware within the same physical subnet may result in channel mismatch issues during automatic frequency handovers.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  In highly congested industrial plants, the 2.4 GHz spectrum experiences severe attenuation and multipath interference from steel structures. To maintain optimal throughput for fast-roaming I\/O devices, it is recommended to bind these critical networks to the 5 GHz band. Keep in mind that 5 GHz signals have shorter propagation distances; therefore, accurate path loss calculations are necessary when designing the physical placement of the hotspots.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  To prevent damage from electrostatic discharge (ESD) or atmospheric surges, the DIN rail must have an uninterrupted path to the primary plant ground. Use low-loss coaxial cabling (such as LMR-400 equivalent) for any remote-mounted antenna deployments, and ensure coaxial surge protectors are installed inline and correctly grounded at the panel entry point.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all primary and secondary power supplies feeding the enclosure prior to mounting or wiring the communication hardware. Never connect or disconnect RF coaxial cables while the hotspot is powered on; doing so can cause permanent damage to the RF transmitter module.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      Mount the unit securely onto a standard 35mm DIN rail within a clean, dry, NEMA or IP-rated industrial enclosure.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      Connect the plant ground wire to the dedicated grounding screw on the extruded aluminum chassis before making any power or network connections.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      Attach high-quality RP-SMA industrial antennas to the RF ports. Hand-tighten the connectors, ensuring a secure and weather-tight connection.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      Terminate the Ethernet RJ45 network cable and connect the DC power supply, adhering strictly to the rated voltage ranges specified on the manufacturer label.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":53076256227691,"sku":"RLX2-IHNF-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/rlx2-ihnf-a-2f1pzcp1lom.png?v=1775727293","url":"https:\/\/www.plcprotech.com\/fr\/products\/prosoft-rlx2-ihnf-a-fast-industrial-hotspot-fcc-model","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}