{"product_id":"rps6u-200-582-500-013-vibro-meter-vm600-rack-power-supply-110-230-vac","title":"Alimentation de rack Vibro-Meter VM600 RPS6U 200-582-500-013 (110\/230 VAC)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U 200-582-500-013 (RPS6U)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the primary AC-to-DC power conversion module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter VM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emachinery protection system. Engineered for high-availability industrial environments, this 6U-high rack-mounted power supply converts standard plant AC mains (110\/230 VAC) into the regulated DC voltages required by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e, and various I\/O cards. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed with high efficiency and low electromagnetic emission, ensuring that sensitive vibration monitoring electronics receive \"clean\" power free from mains-borne interference, which is critical for preventing false trips in power generation and petrochemical applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-582-500-013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant is the high-voltage AC version, offering versatile installation options for global industrial standards.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal AC Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an auto-sensing or jumper-selectable input range, allowing it to operate seamlessly on both 110 VAC (North America\/Japan) and 230 VAC (Europe\/Asia) grids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VM600 rack architecture allows for the installation of two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in a redundant configuration. In this setup, the units share the load; if one fails, the other instantaneously assumes the full load without interrupting the machinery protection functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors output voltage levels and internal temperature. It communicates its health status via the VM600 backplane to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecard, allowing for predictive maintenance alerts before a power failure occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with over-voltage, over-current, and short-circuit protection, safeguarding the entire rack's expensive processing modules from external electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRPS6U 200-582-500-013\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSwitzerland\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110\/230 VAC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 VDC, +12 VDC, -12 VDC (Rack Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6U VME Rack Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix an AC RPS6U and a DC RPS6U in the same VM600 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The VM600 backplane is designed to accept redundant power from different sources. Using one\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-582-500-013 (AC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand one DC-version (e.g., 24 VDC) provides the highest level of reliability, protecting the system against the loss of a specific power bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a solid red \"Fault\" LED on the front panel indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA red LED usually indicates an output voltage out of tolerance or an internal over-temperature condition. Check the rack's total power consumption (too many cards) or ensure that the rack's cooling fans are operational and the air filters are clean.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a specific slot for the RPS6U?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn a standard VM600 rack, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supplies are installed in the designated power slots at the far left or far right of the rack, separate from the measurement and CPU cards.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor true redundancy, ensure that each\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis fed from a different mains circuit (e.g., UPS A and UPS B). Wiring both units to the same breaker defeats the purpose of the dual power supply architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding for Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe rack frame must be securely bonded to the protective earth (PE). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelies on the rack's ground path to drain EMI and protect against internal high-voltage leakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVentilation Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-power racks generate significant heat. Ensure a minimum of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1U (44.45 mm)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof empty space above and below the VM600 rack if no active fan tray is used, or verify that the fan tray is pulling air effectively across the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eheat sinks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRPS6U 200-582-500-013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis distinguished by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHigh MTBF (Mean Time Between Failures)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand its role in SIL-rated systems. Because the power supply is the only component shared by all cards in a rack, its reliability is paramount. Vibro-Meter uses industrial-grade capacitors and heavy-duty magnetic components that are rated for continuous operation at 65 deg C, ensuring that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSI (Turbine Supervisory Instrumentation)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem remains online even in the high-ambient-heat conditions of a turbine deck.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695206429035,"sku":"SIM-275A 200-582-500-013","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-vm600-rps6u-sim-275a-200-582-500-013-power-supply-module-m50txdanj0i_d47c6185-4f1e-4a75-a1e0-34850c27ff58.jpg?v=1766130702","url":"https:\/\/www.plcprotech.com\/fr\/products\/rps6u-200-582-500-013-vibro-meter-vm600-rack-power-supply-110-230-vac","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}