{"product_id":"schneider-altistart-22-ats22d88s6-soft-starter","title":"Démarreur progressif Schneider Altistart 22 ATS22D88S6","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATS22D88S6\u003c\/strong\u003e is a \u003cstrong\u003eSoft Starter\u003c\/strong\u003e from the \u003cstrong\u003eAltistart 22\u003c\/strong\u003e series, designed for the controlled acceleration and deceleration of three-phase asynchronous motors. By managing the voltage and torque during the start sequence, this device prevents mechanical shocks and reduces electrical inrush currents, thereby extending the lifespan of motors, belts, and gearboxes. The unit is rated for an operational current of 88 A and supports a wide supply voltage range of 230V to 600V, accommodating motor power ratings from 22 kW to 55 kW. It features an integrated bypass contactor, which minimizes heat dissipation during steady-state operation, making it an efficient solution for industrial motor control.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated bypass contactor for thermal efficiency\u003c\/li\u003e\n\u003cli\u003eSoft start and soft stop control to reduce mechanical stress\u003c\/li\u003e\n\u003cli\u003eWide voltage range (230-600V) for global application flexibility\u003c\/li\u003e\n\u003cli\u003eCompact physical design for high-density cabinet installation\u003c\/li\u003e\n\u003cli\u003eSimplified configuration through display and keypad interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal pumps and fan systems\u003c\/li\u003e\n\u003cli\u003eConveyors and material handling equipment\u003c\/li\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMixers and agitators\u003c\/li\u003e\n\u003cli\u003eGeneral industrial machinery requiring controlled starts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eATS22D88S6\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current\u003c\/td\u003e\n\u003ctd\u003e88 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e230-600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power Rating\u003c\/td\u003e\n\u003ctd\u003e22-55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e84798997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e36 x 31 x 23.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install in a vertical position with adequate clearance above and below the unit to facilitate airflow through the cooling vents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e If installed in an enclosure, ensure proper ventilation to prevent ambient temperature from exceeding the unit's rated operating threshold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect main power inputs and motor outputs according to the terminal markings. Ensure connections are tightened to specified torque values.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure the device to a common ground point within the control panel to satisfy EMC requirements and safety standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize the built-in display to set parameters such as ramp-up time, ramp-down time, and current limit based on the motor's specific load requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104567550315,"sku":"ATS22D88S6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats22d88s6-cvui4wkcqgv.png?v=1776162082","url":"https:\/\/www.plcprotech.com\/fr\/products\/schneider-altistart-22-ats22d88s6-soft-starter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}