{"product_id":"schneider-altistart-u01-atsu01n212lt-soft-starter","title":"Démarreur progressif Schneider Altistart U01 ATSU01N212LT","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATSU01N212LT\u003c\/strong\u003e is a compact \u003cstrong\u003eSoft Starter\u003c\/strong\u003e from the \u003cstrong\u003eAltistart U01\u003c\/strong\u003e range, engineered for the smooth starting and stopping of three-phase asynchronous motors. By regulating the voltage ramp, this device effectively mitigates torque transients and high inrush currents, protecting mechanical components such as belts, chains, and gearboxes. It is designed for motors with a power rating between 2.2 kW and 5.5 kW, operating within a wide voltage supply range of 200V to 480V and a rated operational current of 12 A. Its ultra-compact design is specifically optimized for space-constrained control panels in various industrial sectors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage ramp regulation for smooth motor acceleration\u003c\/li\u003e\n\u003cli\u003eIntegrated bypass contactor to optimize thermal performance\u003c\/li\u003e\n\u003cli\u003eUltra-compact form factor for high-density DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eEasy-to-adjust starting time and deceleration settings\u003c\/li\u003e\n\u003cli\u003eSimplifies motor control for three-phase asynchronous machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmall conveyors and material handling systems\u003c\/li\u003e\n\u003cli\u003eCentrifugal and axial fans\u003c\/li\u003e\n\u003cli\u003ePumps and fluid processing equipment\u003c\/li\u003e\n\u003cli\u003ePackaging and labeling machinery\u003c\/li\u003e\n\u003cli\u003eLight-duty industrial automation tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003eU01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eATSU01N212LT\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e200-480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power Rating\u003c\/td\u003e\n\u003ctd\u003e2.2-5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e84798997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e15 x 17.5 x 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for standard DIN rail installation. Maintain a vertical orientation to ensure proper heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure sufficient space around the unit to allow for natural convection; do not obstruct the housing vents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Verify motor and power supply connections match the required terminal designations. Use appropriate wire gauges to handle the 12 A nominal current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure a reliable chassis ground to the system earth to maintain electrical safety and EMC integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e Use the front-mounted potentiometers to fine-tune the acceleration\/deceleration ramp according to the specific load requirements of the motor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104567419243,"sku":"ATSU01N212LT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atsu01n212lt-ow24xsvrt5r.png?v=1776162129","url":"https:\/\/www.plcprotech.com\/fr\/products\/schneider-altistart-u01-atsu01n212lt-soft-starter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}