{"product_id":"schneider-electric-ats22c17s6-altistart-22-soft-starter","title":"Démarreur progressif Altistart 22 Schneider Electric ATS22C17S6","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATS22C17S6\u003c\/strong\u003e is an \u003cstrong\u003eAltistart 22\u003c\/strong\u003e series \u003cstrong\u003esoft starter\u003c\/strong\u003e engineered for the controlled acceleration and deceleration of asynchronous motors. Operating within a supply voltage range of 230 - 600 V, this device provides a rated current capacity of 170 A, supporting motor loads between 45 kW and 110 kW. By regulating the voltage applied to the motor terminals during start-up, it mitigates mechanical shock to drivetrains and reduces electrical inrush currents on the supply network. It is designed for integration into standard industrial control cabinets, optimizing energy efficiency while providing integrated electrical fault protection for connected equipment.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated for 170 A continuous operational current\u003c\/li\u003e\n\u003cli\u003eSupports a wide operating supply voltage range of 230 - 600 V\u003c\/li\u003e\n\u003cli\u003eEngineered for asynchronous motor capacities from 45 kW to 110 kW\u003c\/li\u003e\n\u003cli\u003eReduces mechanical drivetrain stress and electrical network voltage drops during start-up\u003c\/li\u003e\n\u003cli\u003eCompact physical profile for high-density control panel integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal pumps and fluid handling systems\u003c\/li\u003e\n\u003cli\u003eIndustrial fans and ventilation networks\u003c\/li\u003e\n\u003cli\u003eConveyors and material handling equipment\u003c\/li\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eGeneral purpose industrial motor control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e170 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e230 - 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Range\u003c\/td\u003e\n\u003ctd\u003e45 - 110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e13.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e41.00 cm x 33.00 cm x 25.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e84798997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the unit vertically to facilitate natural convection cooling across the internal heatsinks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain adequate spatial clearance above and below the device as specified in the OEM manual to prevent thermal accumulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Size all power cables appropriately for 170 A continuous operation and ensure terminals are tightened to the specified torque rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the operating environment remains free from conductive dust and corrosive gases, keeping ambient temperatures within the specified operational limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Integrate appropriate upstream short-circuit protection devices in accordance with local electrical safety standards and load requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104559554923,"sku":"ATS22C17S6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats22c17s6-zvaazbp0oaf.png?v=1776162054","url":"https:\/\/www.plcprotech.com\/fr\/products\/schneider-electric-ats22c17s6-altistart-22-soft-starter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}