{"product_id":"schneider-modicon-premium-tsxdey32d2kc-digital-module","title":"Module numérique Schneider Modicon Premium TSXDEY32D2KC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXDEY32D2KC\u003c\/strong\u003e is a high-density \u003cstrong\u003ediscrete input module\u003c\/strong\u003e for the \u003cstrong\u003eModicon Premium\u003c\/strong\u003e automation platform, engineered for reliable signal acquisition in industrial control systems. This module features \u003cstrong\u003e32 isolated current sink inputs\u003c\/strong\u003e operating at \u003cstrong\u003e24 V DC\u003c\/strong\u003e with a low current consumption of \u003cstrong\u003e3.5 mA\u003c\/strong\u003e per input. Designed to interface effectively with field sensors and switches, the \u003cstrong\u003eTSXDEY32D2KC\u003c\/strong\u003e provides robust isolation to protect the PLC backplane from external electrical interference. Its efficient design makes it a standard choice for expanding I\/O capacity in demanding \u003cstrong\u003eModicon Premium\u003c\/strong\u003e rack configurations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 isolated discrete inputs\u003c\/strong\u003e (current sink configuration).\u003c\/li\u003e\n\u003cli\u003eOperates at \u003cstrong\u003e24 V DC\u003c\/strong\u003e nominal input voltage.\u003c\/li\u003e\n\u003cli\u003eLow power consumption at \u003cstrong\u003e3.5 mA\u003c\/strong\u003e per channel.\u003c\/li\u003e\n\u003cli\u003eStandardized for integration with \u003cstrong\u003eModicon Premium\u003c\/strong\u003e PLC architectures.\u003c\/li\u003e\n\u003cli\u003eDesigned for high-density I\/O requirements in industrial automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial machinery and conveyor control systems.\u003c\/li\u003e\n\u003cli\u003eDistributed monitoring of sensors and limit switches.\u003c\/li\u003e\n\u003cli\u003eProcess automation requiring isolated digital signal inputs.\u003c\/li\u003e\n\u003cli\u003eI\/O capacity expansion for Modicon Premium PLC racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e32 Isolated current sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumption\u003c\/td\u003e\n\u003ctd\u003e3.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18.00 x 25.50 x 5.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module into the designated slot on the \u003cstrong\u003eModicon Premium\u003c\/strong\u003e rack, ensuring the rear connector is properly seated to the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cabling for input signals to minimize electromagnetic interference, adhering to standard industrial wiring practices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Ensure the common return path for the current sink inputs is correctly established to maintain input isolation integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Monitor the front-panel LED indicators to verify the status of individual inputs during system operation and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Confirm that the 24 V DC supply is within the operational range before powering on the rack to prevent damage to the module circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104570728811,"sku":"TSXDEY32D2KC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxdey32d2kc-cogfkt51su5.png?v=1776163870","url":"https:\/\/www.plcprotech.com\/fr\/products\/schneider-modicon-premium-tsxdey32d2kc-digital-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}