{"product_id":"schneider-tsxpsi2010-modicon-premium-atrium-power-supply-module","title":"Module d'alimentation Atrium Modicon Premium TSXPSI2010 Schneider","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSI2010\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a specialized 24 VDC power supply module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Premium\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAtrium slot PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. Specifically designed for \"Atrium slot PLC Unity\" configurations, this module provides the critical voltage stabilization and current regulation required to power Atrium processors residing in PC-based automation slots. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSI2010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a robust electrical interface, shielding sensitive PLC logic from the electrical noise and fluctuations inherent in industrial PC power buses. With a high inrush current tolerance and integrated short-circuit protection via a 2 A time-delay fuse, it ensures that the control system remains operational in demanding environments such as automotive assembly, material handling, and complex machine control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSI2010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware architecture is built for precision power delivery and system safety:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates on a nominal 24 VDC input with a wide tolerance band (19.2 V to 30 V), accommodating standard industrial battery or rectified power sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMicrobreak Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned with internal capacitance to bridge voltage dips of up to 7 ms, preventing system resets during brief power interruptions or supply switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures specialized electrical interfaces including one female\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSUB-D 9\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector and one female\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSUB-D 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector dedicated to the supply voltage input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes an internal 2 A time-delay fuse to protect against overcurrent and short-circuits, alongside high immunity to inrush currents (100 A at 25 deg C).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAtrium Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eForm-factored to integrate seamlessly with Atrium slot PLC architectures, providing the \"Unity\" compatible power layer for PC-integrated safety and control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXPSI2010\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium \/ Atrium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.2 to 30 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 1.1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 A at 25 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A Fuse (Time Delay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSUB-D 9 and SUB-D 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAltitude Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 2000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TSXPSI2010 compatible with standard Modicon Premium RKY racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific model is designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAtrium slot PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. Standard Modicon Premium racks typically use the TSXPSY series (e.g., TSXPSY2600). The TSXPSI2010 is intended for the PC-based slot-PLC versions of the Modicon architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle brief power losses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module has an immunity to microbreaks of up to 7 ms at 24 V. If the supply voltage drops for a duration shorter than this, the internal energy storage maintains the processor's operation without a system halt.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of cabling is required for the SUB-D 3 connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SUB-D 3 connector is used for the primary 24 VDC supply input. It is critical to use properly shielded, twisted-pair cabling to minimize EMI and ensure that the \"Unity\" software diagnostics for power health remain accurate.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current Planning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen sizing your 24 VDC bulk power supply, account for the 100 A inrush current of the TSXPSI2010. While this spike lasts only milliseconds (3 A²s), a power supply with overly sensitive \"electronic fuse\" trip settings may fail to start.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the industrial PC or enclosure housing the Atrium slot PLC has adequate airflow. The TSXPSI2010 is rated for operation up to 60 deg C; however, if the PC's internal ambient temperature exceeds this due to high CPU load, the power supply module's lifespan may be reduced.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SUB-D connectors must be securely tightened to the chassis. The metal shell of the SUB-D connector provides the necessary path to ground for electromagnetic interference. A loose connector can lead to intermittent \"I\/O Fault\" or \"Power Supply Fault\" LEDs on the Atrium processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the module fails to power up, check the internal 2 A time-delay fuse. Always replace it with an identical rating (IEC 1131-2 compliant) to maintain the safety certification and protective characteristics of the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574169451,"sku":"TSXPSI2010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxpsi2010-vcvnyoydkty.png?v=1776164428","url":"https:\/\/www.plcprotech.com\/fr\/products\/schneider-tsxpsi2010-modicon-premium-atrium-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}