{"product_id":"siemens-3rk1300-0js01-1aa3-simatic-et-200x-motor-starter","title":"Démarreur moteur Simatic ET 200X Siemens 3RK1300-0JS01-1AA3","description":"\u003cp\u003eThe \u003cstrong\u003e3RK1300-0JS01-1AA3\u003c\/strong\u003e is an electro-mechanical reversing starter module from the \u003cstrong\u003eSIMATIC ET 200X\u003c\/strong\u003e distributed I\/O series. Engineered for compact, decentralized motor control, this module is specifically designed to manage small motor loads with a current setting range of \u003cstrong\u003e0.7 to 1.0A\u003c\/strong\u003e. It is rated for \u003cstrong\u003eAC-3 operation\u003c\/strong\u003e, supporting power ratings up to \u003cstrong\u003e0.25 kW at 400V\u003c\/strong\u003e. The module features an integrated brake contact intended for internally supplied brakes, and is equipped with standardized 9-pole interfaces for both the motor feeder and power supply, facilitating quick installation in distributed drive architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReversing Functionality:\u003c\/strong\u003e Integrated electro-mechanical design allows for forward and reverse motor operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Integration:\u003c\/strong\u003e Optimized for ET 200X distributed I\/O platforms, reducing central cabinet wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrake Control:\u003c\/strong\u003e Includes a dedicated brake contact for controlling internally supplied motor brakes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardized Interfaces:\u003c\/strong\u003e Equipped with robust 9-pole motor and power connectors for simplified field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Range:\u003c\/strong\u003e Precise current setting range of 0.7A to 1.0A to protect specific motor loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDecentralized drive control in modular production machines.\u003c\/li\u003e\n\u003cli\u003eConveyor technology and small motor positioning tasks.\u003c\/li\u003e\n\u003cli\u003eIndustrial systems requiring distributed reversing starters without central MCC cabinets.\u003c\/li\u003e\n\u003cli\u003eRetrofit applications for existing ET 200X installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100.069%; height: 274.313px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 34.8405%; height: 19.5938px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 62.1794%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003eSimatic ET200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003eET 200X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003eEM 300 RS (Reversing Starter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eCurrent Setting Range\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003e0.7 ... 1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003ePower Rating (AC-3\/400V)\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003e0.25 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eInterfaces\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003e9-pole motor feeder, 9-pole power connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eIntegrated Features\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003eBrake contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eProduct Phase\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003e13.40 cm x 11.00 cm x 5.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003e85365080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8405%; height: 19.5938px;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd style=\"width: 62.1794%; height: 19.5938px;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the module onto the ET 200X base module; ensure the mechanical locking mechanism is fully engaged to maintain environmental integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use compatible 9-pole connectors for power and motor feeds. Verify that cable sizing adheres to the 0.7-1.0A current setting limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrake Wiring:\u003c\/strong\u003e When using the brake contact, ensure the voltage levels of the brake align with the internal supply specifications of the ET 200X system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Although designed for decentralized mounting, ensure the module is installed in a location with adequate airflow, away from direct sources of extreme heat.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716779929963,"sku":"3RK1300-0JS01-1AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3rk1300-0js01-1aa3-msbwnm5tn4e_a7ab1144-fcc3-4a79-9bf7-8d809b7d9697.jpg?v=1767089498","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-3rk1300-0js01-1aa3-simatic-et-200x-motor-starter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}