{"product_id":"siemens-6av3627-1nk00-0ax0-simatic-hmi-tp27-6-touch-panel","title":"Siemens 6AV3627-1NK00-0AX0 SIMATIC HMI TP27-6 Touch Panel","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV3627-1NK00-0AX0 is a Touch Panel TP27-6 from the SIMATIC HMI series, designed for operator control and monitoring in industrial automation systems. This HMI unit features a \u003cstrong\u003e5.7-inch STN monochrome LC display\u003c\/strong\u003e with a resolution of \u003cstrong\u003e320 x 240 pixels\u003c\/strong\u003e, providing clear visualization for process data. It is equipped with \u003cstrong\u003e1 MB of Flash-EPROM\u003c\/strong\u003e memory for storing project configurations and data. The robust construction ensures reliable performance in demanding manufacturing environments. Note that this product is considered obsolete, with the designated successor being the 6AV3627-1NK00-2AX0.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003e5.7-inch monochrome Super-Twisted Nematic (STN) display\u003c\/li\u003e\n\u003cli\u003e320 x 240 pixel screen resolution\u003c\/li\u003e\n\u003cli\u003eIntegrated touch functionality for operator input\u003c\/li\u003e\n\u003cli\u003e1 MB of onboard Flash-EPROM memory\u003c\/li\u003e\n\u003cli\u003eDesigned for panel mounting in control cabinets\u003c\/li\u003e\n\u003cli\u003ePart of the established SIMATIC HMI family\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003eMachine control and process visualization\u003c\/li\u003e\n\u003cli\u003eData entry and parameter adjustment for PLCs\u003c\/li\u003e\n\u003cli\u003eAlarm and status monitoring systems\u003c\/li\u003e\n\u003cli\u003eSmall to medium-sized automation applications\u003c\/li\u003e\n\u003cli\u003eIntegration into legacy Siemens automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC HMI TP27 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eTouch Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSTN Monochrome LC Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eScreen Diagonal\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e5.7 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e320 x 240 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e1 MB Flash-EPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSuccessor Part Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e6AV3627-1NK00-2AX0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e1.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e14.7 x 6.2 x 16.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px 16px; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation, wiring, and maintenance must be performed by qualified personnel only. De-energize all power sources and follow Lockout\/Tagout (LOTO) procedures before accessing equipment. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003ePanel Preparation:\u003c\/strong\u003e Prepare the control cabinet panel cutout according to the manufacturer's specified dimensions. Ensure the mounting surface is clean, flat, and free of debris to achieve a proper seal.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the HMI into the panel cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a diagonal pattern to ensure uniform pressure on the gasket for a proper IP rating.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional earth (FE) terminal on the HMI chassis to the main protective earth busbar of the control cabinet using a low-impedance conductor. A secure ground connection is critical for noise immunity and safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the specified DC power supply to the power terminals on the rear of the unit. Verify the voltage and polarity are correct before applying power. Use appropriately sized conductors and ensure connections are secure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eCommunications:\u003c\/strong\u003e Connect the communication cable (e.g., PROFIBUS, MPI) to the corresponding port. Ensure proper cable shielding and grounding practices are followed to prevent interference. Route communication cables separately from high-voltage power lines.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716743688555,"sku":"6AV3627-1NK00-0AX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av3627-1nk00-0ax0-2g1t2v1qchb_7a86f156-e7c5-4eb6-b729-a727677713ca.jpg?v=1767088598","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av3627-1nk00-0ax0-simatic-hmi-tp27-6-touch-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}