{"product_id":"siemens-6av3637-1ll00-0fx1-simatic-hmi-op37-operator-panel","title":"Siemens 6AV3637-1LL00-0FX1 Panneau opérateur SIMATIC HMI OP37","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV3637-1LL00-0FX1 is an operator panel from the SIMATIC HMI OP37 series, designed for machine-level visualization and control in industrial settings. This unit is equipped with a \u003cstrong\u003ePentium 100 MHz processor\u003c\/strong\u003e and \u003cstrong\u003e8 MB of RAM\u003c\/strong\u003e to manage process control applications. It features a \u003cstrong\u003e10.4-inch STN color display\u003c\/strong\u003e with a resolution of 640 x 480 pixels for clear data representation. For data storage and transfer, the panel includes an integrated floppy disk drive and does not contain a hard drive. Operation is managed through a durable, key-based interface, suitable for demanding production environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003e10.4-inch STN color graphical display\u003c\/li\u003e\n\u003cli\u003e640 x 480 pixel display resolution\u003c\/li\u003e\n\u003cli\u003ePowered by a Pentium 100 MHz processor\u003c\/li\u003e\n\u003cli\u003eEquipped with 8 MB of system RAM\u003c\/li\u003e\n\u003cli\u003e2048 kbyte user memory for applications\u003c\/li\u003e\n\u003cli\u003ePhysical key-based operator controls\u003c\/li\u003e\n\u003cli\u003eIntegrated floppy disk drive for data handling\u003c\/li\u003e\n\u003cli\u003eRequires a 24V DC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003eMachine control and monitoring\u003c\/li\u003e\n\u003cli\u003eProcess visualization systems\u003c\/li\u003e\n\u003cli\u003eFactory automation and data entry\u003c\/li\u003e\n\u003cli\u003eSupervisory control and data acquisition (SCADA) interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; color: #1a365d;\"\u003eGeneral Information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eSIMATIC HMI OP37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eOperator Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003ePredecessor Model\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e6AV3637-1LL00-0FX0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; color: #1a365d;\"\u003eProcessor \u0026amp; Memory\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003ePentium 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eSystem RAM\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eUser Memory\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e2048 kbyte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; color: #1a365d;\"\u003eDisplay \u0026amp; Interface\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eSTN Color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eScreen Diagonal\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e10.4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eDisplay Colors\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eOperator Input\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eKeys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; color: #1a365d;\"\u003eElectrical\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; color: #1a365d;\"\u003ePhysical \u0026amp; Logistics\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e40.5 x 57.0 x 25.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e7.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; color: #1a365d;\"\u003eCompliance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; background-color: #f7fafc; color: #2d3748; font-weight: bold; width: 40%;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 16px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always follow local Lockout\/Tagout (LOTO) procedures.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Isolate and de-energize all power sources to the control cabinet or mounting location. Verify the absence of voltage before proceeding.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003ePrepare Panel Cutout:\u003c\/strong\u003e Ensure the mounting cutout in the enclosure panel corresponds to the HMI's required dimensions. Clean the mounting surface to ensure a proper seal.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eMount the HMI:\u003c\/strong\u003e Insert the operator panel into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to maintain the IP rating.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Protective Earth (PE):\u003c\/strong\u003e Connect a low-impedance protective earth conductor to the designated PE terminal on the HMI chassis. This is critical for safety and noise immunity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect the 24V DC power supply to the designated power terminals. Ensure correct polarity is observed. Use appropriately sized conductors for the load.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Communication Cables:\u003c\/strong\u003e Connect the necessary communication cables (e.g., PROFIBUS, MPI) to their respective ports. Ensure proper shielding and grounding practices are followed to prevent interference.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eFinal Checks and Power-Up:\u003c\/strong\u003e Verify all connections are secure. Remove LOTO devices and re-energize the cabinet. The HMI should power on and begin its startup sequence. Proceed with software configuration and testing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716462473579,"sku":"6AV3637-1LL00-0FX1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av3637-1ll00-0fx1-kr3eifvragt_5848f411-c18e-4ded-8b48-0b3bc35cb185.jpg?v=1767083139","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av3637-1ll00-0fx1-simatic-hmi-op37-operator-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}