{"product_id":"siemens-6av6643-0db01-1ax1-simatic-mp-277-8-key-multi-panel","title":"Siemens 6AV6643-0DB01-1AX1 SIMATIC MP 277 8\" Key Multi Panel","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV6643-0DB01-1AX1 is a SIMATIC MP 277 8\" Key Multi Panel designed for machine-level operator control and monitoring applications. This Human Machine Interface (HMI) features a \u003cstrong\u003e7.5-inch TFT color display\u003c\/strong\u003e and is operated via a robust physical keypad for reliable, tactile input. It is equipped with \u003cstrong\u003e6 MB of retentive configuration memory\u003c\/strong\u003e and supports both \u003cstrong\u003ePROFINET and PROFIBUS\u003c\/strong\u003e network communications. Configuration is performed using WinCC flexible 2005 Standard SP1 or higher. Please note, this model is a \u003cstrong\u003ePhase-Out\u003c\/strong\u003e product, succeeded by part number 6AV6643-0DB01-1AX2.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e7.5-inch TFT display with 65,536 colors for clear process visualization.\u003c\/li\u003e\n  \u003cli\u003eKey-based operation for precise control in industrial environments.\u003c\/li\u003e\n  \u003cli\u003e6 MB (6144 kbyte) of integrated user memory for HMI applications.\u003c\/li\u003e\n  \u003cli\u003eDual protocol support for flexible integration via PROFINET and PROFIBUS.\u003c\/li\u003e\n  \u003cli\u003eNominal 24V DC power supply requirement.\u003c\/li\u003e\n  \u003cli\u003eRetentive memory ensures data persistence through power cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eMachine-level operator control and process monitoring.\u003c\/li\u003e\n  \u003cli\u003eData entry and parameter adjustment for automated equipment.\u003c\/li\u003e\n  \u003cli\u003eAlarm management and system diagnostics visualization.\u003c\/li\u003e\n  \u003cli\u003eIntegration into factory automation and process control networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead style=\"background-color: #f7fafc;\"\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; font-weight: bold; color: #1a365d;\"\u003eGeneral\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSIMATIC HMI Multi panels 270 series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eMP 277 8\" Key\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6AV6643-0DB01-1AX1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; font-weight: bold; color: #1a365d;\"\u003eDisplay \u0026amp; Operator Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eTFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eScreen Diagonal\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e7.5 inch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e640 x 480 pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eDisplay Colors\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e65536\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eOperator Input\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eKeypad\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; font-weight: bold; color: #1a365d;\"\u003eMemory \u0026amp; Communication\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eConfiguration Memory\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6 MB (6144 kbyte)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eSupported Protocols\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePROFINET, PROFIBUS\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; font-weight: bold; color: #1a365d;\"\u003eElectrical\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e24V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; font-weight: bold; color: #1a365d;\"\u003eProduct Lifecycle\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eSuccessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6AV6643-0DB01-1AX2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003ePredecessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6AV6643-0DB01-1AX0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; font-weight: bold; color: #1a365d;\"\u003eLogistics\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e46.2 x 33.5 x 13.4 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e3.05 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; padding-left: 25px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e5D002\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect all power sources and implement Lockout\/Tagout (LOTO) procedures before installation or maintenance. Work must be performed by qualified personnel only. Failure to de-energize equipment can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePanel Cutout:\u003c\/strong\u003e Prepare the control cabinet panel cutout according to the manufacturer's dimensional drawings. Ensure all metal shavings are removed from the enclosure to prevent short circuits.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the HMI into the cutout from the front of the panel. Secure it evenly using all provided mounting clamps, tightening them to the specified torque to ensure a proper seal (IP rating).\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional earth (FE) terminal on the HMI chassis to the main protective earth busbar of the control cabinet using a low-impedance conductor. This is critical for noise immunity and safety.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24V DC power supply to the designated terminals. Ensure correct polarity. Use a dedicated, regulated power supply unit (PSU) rated for industrial environments.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eNetwork Connection:\u003c\/strong\u003e Connect the PROFINET or PROFIBUS cables to the corresponding ports. Use shielded cables and ensure proper shield termination at one end to minimize electromagnetic interference (EMI).\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716676186475,"sku":"6AV6643-0DB01-1AX1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av6643-0db01-1ax1-kvmf001h3zn_ab0f617d-5327-4d38-b055-73f46e13abbf.jpg?v=1767087854","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av6643-0db01-1ax1-simatic-mp-277-8-key-multi-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}