{"product_id":"siemens-6av7611-0ab22-0cf0-simatic-panel-pc-670","title":"Siemens 6AV7611-0AB22-0CF0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens SIMATIC Panel PC 670, model 6AV7611-0AB22-0CF0, designed for industrial human-machine interface (HMI) and control applications. This unit features a \u003cstrong\u003e10-inch TFT display\u003c\/strong\u003e and is powered by a \u003cstrong\u003ePentium III 500 MHz CPU\u003c\/strong\u003e. It is configured with \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e, a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e, and a CD-ROM drive. The system is pre-installed with the Windows 98 operating system in English and is supplied with a European mains power cable for operation on 115-230V AC power sources.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10-inch color TFT display for process visualization.\u003c\/li\u003e\n\u003cli\u003eIntegrated Pentium III 500 MHz processor.\u003c\/li\u003e\n\u003cli\u003e128 MB of system RAM.\u003c\/li\u003e\n\u003cli\u003e20 GB hard drive for application and data storage.\u003c\/li\u003e\n\u003cli\u003eBuilt-in CD-ROM drive for software installation.\u003c\/li\u003e\n\u003cli\u003ePre-loaded with Windows 98 (English).\u003c\/li\u003e\n\u003cli\u003eSupports a wide input voltage range of 115-230V AC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachine-level operator control and monitoring.\u003c\/li\u003e\n\u003cli\u003eProcess visualization and data acquisition (SCADA).\u003c\/li\u003e\n\u003cli\u003eIndustrial data logging and recipe management.\u003c\/li\u003e\n\u003cli\u003eFactory automation control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e6AV7611-0AB22-0CF0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e10-inch TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProcessor (CPU)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePentium III 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e20 GB Hard Drive (HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOptical Drive\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCD-ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eWindows 98 (English)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e115-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eEuropean Mains Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e4.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e45 cm x 35 cm x 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Shock Hazard. Disconnect and lock out all power sources before installation or servicing. Installation must be performed by qualified personnel only. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before beginning installation, ensure the control cabinet or mounting location is completely de-energized, locked out, and tagged out (LOTO). Verify absence of voltage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003ePrepare Panel Cutout:\u003c\/strong\u003e Verify that the panel cutout dimensions match the requirements for the PC 670 chassis. Ensure the mounting surface is clean, flat, and rigid enough to support the unit's weight.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front of the panel. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal and secure fit. Do not overtighten.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Power and Ground:\u003c\/strong\u003e Connect the protective earth (PE) conductor to the designated grounding terminal on the chassis. Connect the supplied mains power cable to the unit's power input and to a properly rated and protected AC power source.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect all required communication, I\/O, and peripheral cables (e.g., Ethernet, keyboard, mouse). Ensure all connectors are fully seated and secured.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eFinal Checks and Power-Up:\u003c\/strong\u003e Close the control cabinet door. Remove the LOTO device and re-energize the main power supply. Power on the Panel PC and verify that the operating system boots correctly.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716412469611,"sku":"6AV7611-0AB22-0CF0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7611-0ab22-0cf0-ugnwdgdwtlm_a0bf9dbd-18ac-4bf9-9a7f-01b9e1d7767e.jpg?v=1767082422","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7611-0ab22-0cf0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}