{"product_id":"siemens-6av7613-0aa10-0ag0-simatic-panel-pc-670-panel-pc","title":"Siemens 6AV7613-0AA10-0AG0 SIMATIC Panel PC 670 Panel PC","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7613-0AA10-0AG0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This unit is equipped with a \u003cstrong\u003e12-inch TFT display\u003c\/strong\u003e, a \u003cstrong\u003e300 MHz Celeron CPU\u003c\/strong\u003e, and is configured with \u003cstrong\u003e64 MB of RAM\u003c\/strong\u003e and a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e. It operates on a nominal \u003cstrong\u003e24 V DC\u003c\/strong\u003e power supply and comes pre-installed with a multi-language version of the Windows 2000 operating system, supporting English, German, French, Italian, and Spanish. This model is an obsolete component, suitable for maintaining or repairing existing legacy automation systems.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003e12-inch TFT color display for process visualization\u003c\/li\u003e\n  \u003cli\u003eIntel Celeron processor operating at 300 MHz\u003c\/li\u003e\n  \u003cli\u003eIntegrated 20 GB hard disk for operating system and application storage\u003c\/li\u003e\n  \u003cli\u003e64 MB of system RAM\u003c\/li\u003e\n  \u003cli\u003ePowered by a 24 V DC supply, common in industrial control cabinets\u003c\/li\u003e\n  \u003cli\u003ePre-loaded with Windows 2000 multi-language operating system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eMachine-level operator control and monitoring\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and data acquisition (SCADA)\u003c\/li\u003e\n  \u003cli\u003eFactory floor information systems\u003c\/li\u003e\n  \u003cli\u003eReplacement unit for existing SIMATIC PC 670 installations\u003c\/li\u003e\n  \u003cli\u003eControl panel integration in manufacturing and process industries\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 10px 12px; border: 1px solid #e2e8f0; background-color: #f8fafc; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 10px 12px; border: 1px solid #e2e8f0; background-color: #f8fafc; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e6AV7613-0AA10-0AG0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e12 inch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eTFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProcessor (CPU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSystem Memory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e64 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e20 GB Hard Drive (HD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWindows 2000 Multi-Language (EN, GER, FR, IT, SP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eN (No License Required)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e35.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e12.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px 16px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 16px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e This equipment is intended for use by qualified personnel only. Disconnect all power sources and follow Lockout\/Tagout (LOTO) procedures before installation, service, or removal. Failure to de-energize the system can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePanel Cutout and Mounting:\u003c\/strong\u003e Prepare the control cabinet panel cutout according to the manufacturer's mechanical drawings. Ensure the mounting surface is clean, flat, and rigid. Secure the Panel PC using all provided mounting clamps, tightening them evenly to ensure a proper seal and prevent chassis distortion.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated terminals. Verify the polarity (+\/-) is correct before energizing. Use appropriately sized conductors and ensure connections are secure to prevent voltage drop and overheating. The power supply should be a stable, regulated source suitable for industrial electronics.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eProtective Earth (PE) Grounding:\u003c\/strong\u003e Connect the chassis to the main protective earth bus bar of the control cabinet using a low-impedance grounding conductor. A proper ground connection is critical for operator safety and electromagnetic compatibility (EMC).\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eVentilation and Clearance:\u003c\/strong\u003e Ensure adequate clearance around the unit's rear housing for heat dissipation. Do not block ventilation openings. Verify that the ambient operating temperature inside the cabinet remains within the device's specified limits to prevent overheating and ensure long-term reliability.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715838144875,"sku":"6AV7613-0AA10-0AG0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7613-0aa10-0ag0-23qmxkg1kxx_2c071998-f1e7-4679-9079-c74823454173.jpg?v=1767072223","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7613-0aa10-0ag0-simatic-panel-pc-670-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}