{"product_id":"siemens-6av7613-0ab32-0af0-simatic-panel-pc-670","title":"Siemens 6AV7613-0AB32-0AF0 SIMATIC Panel PC 670","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6AV7613-0AB32-0AF0\u003c\/strong\u003e is a SIMATIC Panel PC 670 designed for industrial applications, featuring a 12-inch TFT display. This standard configuration unit includes a 20 GB hard drive, a CD-ROM drive, 256 MB of RAM, and is powered by a Pentium III 500 MHz CPU. It operates on a 24 V DC power supply and comes pre-installed with Windows 98 English. The \u003cstrong\u003eSIMATIC Panel PC 670\u003c\/strong\u003e is suitable for human-machine interface (HMI), visualization, and control tasks in various industrial environments.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-inch TFT Display\u003c\/li\u003e\n\u003cli\u003ePentium III 500 MHz CPU\u003c\/li\u003e\n\u003cli\u003e256 MB RAM\u003c\/li\u003e\n\u003cli\u003e20 GB Hard Drive\u003c\/li\u003e\n\u003cli\u003eIntegrated CD-ROM Drive\u003c\/li\u003e\n\u003cli\u003e24 V DC Power Input\u003c\/li\u003e\n\u003cli\u003ePre-installed Windows 98 English Operating System\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Human-Machine Interface (HMI)\u003c\/li\u003e\n\u003cli\u003eProcess Visualization and Monitoring\u003c\/li\u003e\n\u003cli\u003eData Acquisition and Logging\u003c\/li\u003e\n\u003cli\u003eMachine Control and Automation\u003c\/li\u003e\n\u003cli\u003eFactory Automation Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Panel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC670\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6AV7613-0AB32-0AF0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTFT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCPU\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePentium III 500 MHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e256 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eHard Drive Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e20 GB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCD-ROM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows 98 English\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNot specified\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNot specified\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before beginning any installation or maintenance, ensure that all power to the system and the Panel PC is disconnected and locked out according to safety procedures.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the Panel PC securely into a suitable panel cutout or enclosure. Ensure adequate clearance for ventilation and cable routing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated terminals, observing correct polarity. Verify the power source meets the specified voltage and current requirements.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection for the Panel PC chassis to minimize electrical noise and ensure safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePeripheral Connections:\u003c\/strong\u003e Connect necessary peripherals such as keyboards, mice, and network cables to the appropriate ports.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Route all cables neatly and ensure they are secured to prevent strain or accidental disconnection. Separate power and signal cables where possible to reduce interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Ensure the installation environment is within the specified temperature, humidity, and vibration limits for industrial Panel PCs to ensure reliable operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower On:\u003c\/strong\u003e After all connections are verified, re-energize the system and power on the Panel PC. Monitor for proper boot-up and functionality.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715841749355,"sku":"6AV7613-0AB32-0AF0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7613-0ab32-0af0-2lixuwdyvue_c0f9a89d-0914-43e3-942f-5c0b1d11a425.jpg?v=1767072334","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7613-0ab32-0af0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}