{"product_id":"siemens-6av7613-0ae22-0bg0-simatic-panel-pc-670","title":"Siemens 6AV7613-0AE22-0BG0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 16px;\"\u003eThis is a Siemens 6AV7613-0AE22-0BG0 SIMATIC Panel PC 670, an industrial-grade human-machine interface (HMI) designed for machine-level control and visualization tasks. The unit is equipped with a \u003cstrong\u003e12-inch TFT display\u003c\/strong\u003e and is part of the established SIMATIC PC670 series. As an obsolete product, it serves as a critical spare part for maintaining and extending the life of existing automation systems that rely on this specific hardware platform.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated 12-inch TFT color display\u003c\/li\u003e\n\u003cli\u003eRobust construction for industrial environments\u003c\/li\u003e\n\u003cli\u003ePart of the Siemens SIMATIC Panel PC family\u003c\/li\u003e\n\u003cli\u003eDesigned for panel mounting applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess visualization and control\u003c\/li\u003e\n\u003cli\u003eMachine data acquisition and logging\u003c\/li\u003e\n\u003cli\u003eOperator control stations in manufacturing\u003c\/li\u003e\n\u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes\u003c\/li\u003e\n\u003cli\u003eReplacement unit for legacy automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e12-inch TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e4.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e45 cm x 35 cm x 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 16px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 24px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. Ensure the control panel is completely de-energized and locked out (LOTO) before beginning any installation, wiring, or maintenance procedures. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n\u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/span\u003e\n\u003cstrong\u003ePanel Cutout:\u003c\/strong\u003e Verify that the panel cutout dimensions precisely match the requirements for the PC 670 chassis. Ensure the mounting surface is flat, clean, and rigid enough to support the unit's weight and withstand operational vibration.\n\u003c\/li\u003e\n\u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/span\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly in a cross-pattern to ensure a uniform seal against the panel gasket. Do not over-torque the clamps.\n\u003c\/li\u003e\n\u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/span\u003e\n\u003cstrong\u003eProtective Earth (PE) Connection:\u003c\/strong\u003e Connect the chassis to the control panel's protective earth busbar using a low-impedance conductor. This connection is critical for both electrical safety and noise immunity. Use a dedicated grounding stud on the PC chassis if available.\n\u003c\/li\u003e\n\u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/span\u003e\n\u003cstrong\u003ePower Supply Wiring:\u003c\/strong\u003e Connect the specified DC or AC power source to the unit's power input terminal. Ensure the voltage and polarity are correct. Use appropriately sized wiring and route power cables separately from communication and I\/O cables to minimize electromagnetic interference.\n\u003c\/li\u003e\n\u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; font-weight: bold;\"\u003e5\u003c\/span\u003e\n\u003cstrong\u003eInterface Connections:\u003c\/strong\u003e Connect all required communication cables (e.g., Ethernet, PROFIBUS, serial) and peripherals (e.g., keyboard, mouse). Ensure all connectors are fully seated and secured. Use shielded cables for all data communication lines and ensure shields are properly terminated.\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715819925867,"sku":"6AV7613-0AE22-0BG0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7613-0ae22-0bg0-laq4ngv0x1i_afc21e13-4fb7-4cc7-a3a4-8568a2dee9a2.jpg?v=1767071677","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7613-0ae22-0bg0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}