{"product_id":"siemens-6av7614-0aa20-0af0-simatic-panel-pc-670","title":"Siemens 6AV7614-0AA20-0AF0 SIMATIC Panel PC 670","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6AV7614-0AA20-0AF0\u003c\/strong\u003e is a \u003cstrong\u003eSIMATIC Panel PC 670\u003c\/strong\u003e, an industrial panel personal computer designed for human-machine interface (HMI) and control applications. This unit features a \u003cstrong\u003e15-inch TFT touch display\u003c\/strong\u003e, providing an interactive interface for operators. It comes with a standard configuration including a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e, \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e, and is powered by a \u003cstrong\u003eCeleron 300 MHz CPU\u003c\/strong\u003e. The Panel PC operates on a \u003cstrong\u003e24 V DC\u003c\/strong\u003e power supply and is pre-installed with \u003cstrong\u003eWindows 98 English\u003c\/strong\u003e, making it suitable for integration into existing industrial automation systems requiring this specific operating environment.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e15-inch TFT Touch Display\u003c\/li\u003e\n  \u003cli\u003eCeleron 300 MHz CPU\u003c\/li\u003e\n  \u003cli\u003e128 MB RAM\u003c\/li\u003e\n  \u003cli\u003e20 GB Hard Drive\u003c\/li\u003e\n  \u003cli\u003e24 V DC Power Supply\u003c\/li\u003e\n  \u003cli\u003ePre-installed Windows 98 English Operating System\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens SIMATIC Panel PC 670 is typically deployed in industrial environments for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMachine control and visualization\u003c\/li\u003e\n  \u003cli\u003eProcess monitoring and operation\u003c\/li\u003e\n  \u003cli\u003eData acquisition and display\u003c\/li\u003e\n  \u003cli\u003eFactory automation HMI solutions\u003c\/li\u003e\n  \u003cli\u003eIntegration into legacy control systems requiring Windows 98 compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15\" TFT Touch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCPU\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e128 MBYTE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e20 GB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWIN98 English\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNot specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTo be determined\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation ensures reliable operation and longevity of the SIMATIC Panel PC 670. Follow these general guidelines:\u003c\/p\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before beginning any installation or wiring, ensure that all power to the control cabinet or machine is completely de-energized and locked out according to safety procedures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the Panel PC securely into a prepared panel cutout. Ensure adequate clearance for ventilation around the unit to prevent overheating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated terminals, observing correct polarity. Verify the power source meets the specified voltage and current requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the Panel PC chassis. A robust grounding scheme is essential for EMI\/RFI protection and operational safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal and Communication Wiring:\u003c\/strong\u003e Route all signal and communication cables away from power cables to minimize interference. Use shielded cables for sensitive signals where appropriate, connecting the shield to ground at one end.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePeripheral Connections:\u003c\/strong\u003e Connect any required peripherals such as keyboards, mice, or external storage devices to the appropriate ports.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Up and Configuration:\u003c\/strong\u003e After all connections are secure and verified, re-energize the system. The Panel PC should boot into Windows 98. Configure any necessary network settings, drivers, or application software.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Ensure the operating environment meets the Panel PC's specifications for temperature, humidity, and vibration to prevent premature failure.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715894178155,"sku":"6AV7614-0AA20-0AF0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7614-0aa20-0af0-ddrie12ptmy_ff499a3c-65fe-487e-9100-e674b65cc67c.jpg?v=1767074144","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7614-0aa20-0af0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}