{"product_id":"siemens-6av7614-0ab32-0aj0-simatic-panel-pc-670","title":"Siemens 6AV7614-0AB32-0AJ0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis device is a Siemens 6AV7614-0AB32-0AJ0 SIMATIC Panel PC 670, designed for industrial human-machine interface (HMI) and control applications. It features a \u003cstrong\u003e15-inch TFT touch display\u003c\/strong\u003e and is powered by a \u003cstrong\u003ePentium III 500 MHz CPU\u003c\/strong\u003e. This standard configuration includes \u003cstrong\u003e256 MB of RAM\u003c\/strong\u003e, a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e, and an integrated \u003cstrong\u003eCD-ROM\u003c\/strong\u003e drive. The unit operates on a \u003cstrong\u003e24 V DC\u003c\/strong\u003e power supply and comes pre-installed with the \u003cstrong\u003eWindows NT 4.0 English\u003c\/strong\u003e operating system.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n\u003cli\u003e15-inch TFT color display with touch functionality\u003c\/li\u003e\n\u003cli\u003eIntel Pentium III processor operating at 500 MHz\u003c\/li\u003e\n\u003cli\u003e256 MB of installed system RAM\u003c\/li\u003e\n\u003cli\u003e20 GB internal hard drive for OS and application storage\u003c\/li\u003e\n\u003cli\u003eIntegrated CD-ROM optical drive\u003c\/li\u003e\n\u003cli\u003eNominal 24 V DC power supply input\u003c\/li\u003e\n\u003cli\u003ePre-loaded with Windows NT 4.0 (English version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n\u003cli\u003eProcess visualization and control\u003c\/li\u003e\n\u003cli\u003eMachine-level data acquisition and logging\u003c\/li\u003e\n\u003cli\u003eSCADA client terminals\u003c\/li\u003e\n\u003cli\u003eFactory automation control panels\u003c\/li\u003e\n\u003cli\u003eIndustrial information displays\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e6AV7614-0AB32-0AJ0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e15-inch TFT Touch Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProcessor (CPU)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePentium III, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e20 GB Hard Drive (HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOptical Drive\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCD-ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eWindows NT 4.0 (English)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e4.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e48 cm x 38 cm x 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Failure to de-energize equipment before installation can result in severe electrical shock, personnel injury, or damage to the Panel PC and connected systems. Always follow local lock-out\/tag-out (LOTO) procedures.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003eVerify that the control cabinet panel cutout dimensions match the Panel PC's required mounting specifications. Ensure the mounting surface is clean, flat, and rigid.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003eDe-energize the main power supply to the control cabinet and apply appropriate LOTO safety measures. Use a multimeter to confirm zero-energy state at the intended power connection points.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003eCarefully insert the Panel PC into the panel cutout from the front. Ensure the bezel gasket is properly seated against the panel surface to maintain the intended ingress protection rating.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003eFrom the rear of the panel, install and tighten the mounting clamps evenly in a crisscross pattern to ensure uniform pressure on the gasket. Do not overtighten.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003eConnect a low-impedance protective earth (PE) or functional ground wire to the designated grounding terminal on the Panel PC chassis. This is critical for safety and noise immunity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cspan\u003eConnect the 24 V DC power supply wiring to the unit's power input connector, ensuring correct polarity. Use appropriately sized conductors and secure the connections.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n\u003cspan\u003eConnect all required communication, network (Ethernet), and peripheral (USB, serial) cables. Ensure proper cable strain relief and routing away from high-voltage lines.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e8\u003c\/span\u003e\n\u003cspan\u003eAfter verifying all connections are secure, remove LOTO devices and re-energize the control cabinet. Power on the Panel PC and confirm successful boot-up and operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715892015467,"sku":"6AV7614-0AB32-0AJ0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7614-0ab32-0aj0-jzsxr4rqj0q_961f8a40-2306-4127-879e-b0392ab01625.jpg?v=1767074051","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7614-0ab32-0aj0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}