{"product_id":"siemens-6av7614-0af22-0cj0-simatic-panel-pc-670","title":"Siemens 6AV7614-0AF22-0CJ0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7614-0AF22-0CJ0 is a SIMATIC Panel PC 670, an integrated operator panel designed for machine-level visualization and control tasks in industrial environments. This unit features a \u003cstrong\u003e15-inch TFT touch display\u003c\/strong\u003e for intuitive operator interaction. It is equipped with a \u003cstrong\u003ePentium III 500 MHz processor\u003c\/strong\u003e, \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e for application and data storage. The system includes an integrated CD-ROM drive and comes pre-installed with the Windows NT 4.0 English operating system. This configuration is powered by a 115-230 V AC supply and includes a European mains cable.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003e15-inch TFT color display with integrated touch screen\u003c\/li\u003e\n  \u003cli\u003ePowered by a Pentium III 500 MHz CPU\u003c\/li\u003e\n  \u003cli\u003e128 MB of system RAM\u003c\/li\u003e\n  \u003cli\u003e40 GB internal hard drive for storage\u003c\/li\u003e\n  \u003cli\u003eBuilt-in CD-ROM drive for software installation and data access\u003c\/li\u003e\n  \u003cli\u003ePre-loaded with Microsoft Windows NT 4.0 (English)\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range of 115-230 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) for manufacturing lines\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and control in plant automation\u003c\/li\u003e\n  \u003cli\u003eData acquisition and logging terminals\u003c\/li\u003e\n  \u003cli\u003eSCADA client stations\u003c\/li\u003e\n  \u003cli\u003eMachine control panels in OEM equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6AV7614-0AF22-0CJ0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e15-inch TFT Touch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor (CPU)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePentium III 500 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e128 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e40 GB Hard Drive (HD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCD-ROM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWindows NT 4.0 (English)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e115-230 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEuropean Mains Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e12.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Provided)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e35.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin (Estimated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 16px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always follow local Lockout\/Tagout (LOTO) procedures.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePrepare Mounting Location:\u003c\/strong\u003e Ensure the panel cutout dimensions are accurate and the mounting surface is clean, flat, and can support the weight of the unit (12.00 kg). Verify adequate clearance for ventilation and cable routing at the rear of the unit.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the prepared cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure a proper seal and prevent bezel distortion.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect the chassis ground terminal to the control cabinet's protective earth (PE) busbar using a low-impedance conductor. A reliable ground connection is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Power:\u003c\/strong\u003e With the main power source locked out, connect the AC mains cable to the unit's power input terminal. Ensure the source voltage (115-230 V AC) matches the unit's rating. Route the power cable separately from signal and communication cables.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect all required communication (e.g., Ethernet, serial) and I\/O cables. Ensure all connectors are fully seated and secured. Power on the unit only after all connections are made and the enclosure is safely closed.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715893096811,"sku":"6AV7614-0AF22-0CJ0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7614-0af22-0cj0-1u0me1mf1v0_3a4d0271-85fc-42f5-8b77-8a18d2bbd8b4.jpg?v=1767074095","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7614-0af22-0cj0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}