{"product_id":"siemens-6av7615-0af30-0be0-simatic-panel-pc-670","title":"Siemens 6AV7615-0AF30-0BE0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6AV7615-0AF30-0BE0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This standard configuration features a \u003cstrong\u003e15-inch TFT display\u003c\/strong\u003e, a \u003cstrong\u003e300 MHz Celeron CPU\u003c\/strong\u003e, and \u003cstrong\u003e256 MB of RAM\u003c\/strong\u003e. It is equipped with a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e and a CD-ROM drive for data storage and software installation. The unit operates on a 115-230 V power supply and is supplied with a U.S. mains cable. This specific model comes pre-installed with a German-language version of Windows 98 and is noted as an obsolete product, suitable for legacy system maintenance and spare parts inventory.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003e15-inch TFT color display for process visualization\u003c\/li\u003e\n\u003cli\u003eIntel Celeron processor operating at 300 MHz\u003c\/li\u003e\n\u003cli\u003e256 MB of installed RAM\u003c\/li\u003e\n\u003cli\u003e40 GB internal hard drive for operating system and application storage\u003c\/li\u003e\n\u003cli\u003eIntegrated CD-ROM drive\u003c\/li\u003e\n\u003cli\u003eWide input voltage range of 115-230 V AC\u003c\/li\u003e\n\u003cli\u003ePre-installed with Windows 98 (German language)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eMachine-level HMI and operator control\u003c\/li\u003e\n\u003cli\u003eData logging and acquisition systems\u003c\/li\u003e\n\u003cli\u003eSupervisory control in manufacturing lines\u003c\/li\u003e\n\u003cli\u003eProcess visualization in factory automation\u003c\/li\u003e\n\u003cli\u003eReplacement unit for existing legacy SIMATIC PC 670 installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e15-inch TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eProcessor (CPU)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e40 GB Hard Drive (HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eOptical Drive\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCD-ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e115-230 V (Includes U.S. mains cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWindows 98 (German)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e48 x 38 x 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 15px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. Failure to de-energize equipment and follow Lockout\/Tagout (LOTO) procedures before installation can result in severe injury or death. This equipment contains components sensitive to electrostatic discharge (ESD). Use proper ESD protection, including wrist straps and mats, when handling.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePrepare Mounting Location:\u003c\/strong\u003e Ensure the panel cutout dimensions are correct and the mounting surface is clean, flat, and can support the weight of the unit. Verify adequate clearance for ventilation and cable routing behind the panel.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a cross-pattern to ensure a uniform seal against the panel gasket. Do not overtighten.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect the chassis ground terminal on the rear of the Panel PC to the cabinet's protective earth (PE) busbar using a low-impedance conductor. A secure and reliable ground connection is critical for safety and noise immunity.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Power:\u003c\/strong\u003e With the main power source de-energized, connect the supplied mains cable to the power input on the Panel PC. Ensure the source voltage matches the 115-230 V rating of the unit.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect all required communication cables (e.g., Ethernet, serial) and I\/O devices (e.g., keyboard, mouse). Ensure all connectors are fully seated and secured. Power on the system only after all connections are complete and the cabinet is closed.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716274057579,"sku":"6AV7615-0AF30-0BE0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7615-0af30-0be0-50fodibcegf_111d2bdf-6092-4256-9964-038299d3bce5.jpg?v=1767080199","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7615-0af30-0be0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}