{"product_id":"siemens-6av7722-1ac00-0af0-simatic-panel-pc-670","title":"Siemens 6AV7722-1AC00-0AF0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7722-1AC00-0AF0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This standard configuration unit integrates a \u003cstrong\u003e12.1-inch color TFT touch display\u003c\/strong\u003e with a Celeron processor running at \u003cstrong\u003e1.2 GHz\u003c\/strong\u003e. It is equipped with \u003cstrong\u003e128 MB of SDRAM\u003c\/strong\u003e and a \u003cstrong\u003e40 GB EIDE hard drive\u003c\/strong\u003e for data storage and application hosting. The system comes pre-installed with the Windows 98 SE operating system in English and includes a power supply box rated for \u003cstrong\u003e115-230V AC\u003c\/strong\u003e input. Please note that this product is considered obsolete by the manufacturer, making it suitable for legacy system maintenance and spare parts inventory.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eIntegrated 12.1-inch color TFT display with touch screen functionality.\u003c\/li\u003e\n    \u003cli\u003ePowered by a Celeron 1.2 GHz processor.\u003c\/li\u003e\n    \u003cli\u003eIncludes 128 MB of SDRAM-133 memory.\u003c\/li\u003e\n    \u003cli\u003eFeatures a 40 GB EIDE hard disk drive for storage.\u003c\/li\u003e\n    \u003cli\u003ePre-loaded with Windows 98 SE (English) operating system.\u003c\/li\u003e\n    \u003cli\u003eWide input voltage range of 115-230V AC.\u003c\/li\u003e\n    \u003cli\u003eDesigned for panel mounting in industrial enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eMachine-level operator control and monitoring.\u003c\/li\u003e\n    \u003cli\u003eProcess visualization and SCADA systems.\u003c\/li\u003e\n    \u003cli\u003eData acquisition and logging on the factory floor.\u003c\/li\u003e\n    \u003cli\u003eReplacement unit for existing SIMATIC PC 670 installations.\u003c\/li\u003e\n    \u003cli\u003eManufacturing execution systems (MES) terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n            \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eBrand\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eModel\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e6AV7722-1AC00-0AF0\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e12.1-inch Color TFT, Touch\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCeleron 1.2 GHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eMemory (RAM)\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e128 MB SDRAM-133 (1x128MB)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e40 GB HDD EIDE\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eWindows 98 SE, English\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e115-230V AC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e12.00 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e35.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"border: 1px solid #fed7d7; background-color: #fff5f5; padding: 16px; margin-bottom: 24px; border-left: 5px solid #c53030;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect all power sources and implement Lockout\/Tagout (LOTO) procedures before installation or servicing. This unit operates on mains voltage (115-230V AC), which can cause severe injury or death. All work must be performed by qualified personnel.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003ePrepare the panel cutout according to the device's mechanical specifications. Ensure the mounting surface is clean, flat, and can support the weight of the unit.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003eInsert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's recommended torque to ensure a proper seal.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003eConnect a dedicated protective earth (PE) conductor to the designated grounding terminal on the chassis. This is essential for safety and noise immunity.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003eConnect the 115-230V AC power supply cable to the unit's power input connector. Ensure the power source is stable and within the specified voltage and frequency range.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003eConnect all necessary communication and I\/O cables (e.g., Ethernet, serial, USB). Route cables to prevent strain and interference, separating signal cables from high-voltage power lines.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715805311339,"sku":"6AV7722-1AC00-0AF0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7722-1ac00-0af0-hpt1r05fdbq_46f38189-1b29-4612-81b5-46f96b3c34cd.jpg?v=1767071263","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7722-1ac00-0af0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}