{"product_id":"siemens-6av7722-2bb10-0ad0-simatic-panel-pc-670","title":"Siemens 6AV7722-2BB10-0AD0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe Siemens 6AV7722-2BB10-0AD0 is a SIMATIC Panel PC 670 standard configuration designed for industrial HMI and control applications. This unit features a \u003cstrong\u003e12.1-inch color TFT touchscreen\u003c\/strong\u003e display, powered by an Intel \u003cstrong\u003ePentium III 1.26 GHz\u003c\/strong\u003e processor. It is equipped with \u003cstrong\u003e256 MB of SDRAM\u003c\/strong\u003e, a \u003cstrong\u003e40 GB EIDE hard drive\u003c\/strong\u003e, and an integrated DVD-ROM drive. The system is pre-installed with the Windows 2000 multi-language operating system and is designed for a power input of \u003cstrong\u003e115-230V AC\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12.1-inch color TFT display with integrated touchscreen\u003c\/li\u003e\n\u003cli\u003eIntel Pentium III processor operating at 1.26 GHz\u003c\/li\u003e\n\u003cli\u003e256 MB SDRAM-133 system memory\u003c\/li\u003e\n\u003cli\u003e40 GB EIDE internal hard disk drive for data storage\u003c\/li\u003e\n\u003cli\u003eIntegrated DVD-ROM optical drive\u003c\/li\u003e\n\u003cli\u003ePre-installed with Windows 2000 Multi-Language Edition\u003c\/li\u003e\n\u003cli\u003eWide input voltage range of 115-230V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHuman-Machine Interface (HMI) stations\u003c\/li\u003e\n\u003cli\u003eProcess visualization and control systems\u003c\/li\u003e\n\u003cli\u003eData acquisition and logging terminals\u003c\/li\u003e\n\u003cli\u003eManufacturing Execution System (MES) client nodes\u003c\/li\u003e\n\u003cli\u003eSupervisory Control and Data Acquisition (SCADA) systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV7722-2BB10-0AD0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eColor TFT with Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e12.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIntel Pentium III, 1.26 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSystem Memory (RAM)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e256 MB SDRAM-133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e40 GB HDD EIDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOptical Drive\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDVD-ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWindows 2000 (Multi-Language)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e115-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIncluded Power Cable\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eUS Mains Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e12.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e48.0 x 29.0 x 15.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eN (No License Required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e48 x 29 x 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING: RISK OF ELECTRIC SHOCK\u003c\/strong\u003e\n\u003cp style=\"color: #c53030; margin-top: 8px; margin-bottom: 0;\"\u003eDisconnect all power sources before installation or servicing. This equipment is intended for use by qualified personnel only. Adhere to all local and national safety regulations, including Lockout\/Tagout (LOTO) procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"color: #2d3748; padding-left: 0; list-style: none;\"\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePanel Cutout and Mounting:\u003c\/strong\u003e Prepare the control cabinet panel cutout according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and free of debris. Install the Panel PC into the cutout and secure it evenly using all provided mounting clamps to maintain the specified front panel protection rating.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eProtective Earth (PE) Connection:\u003c\/strong\u003e Connect the chassis to the control cabinet's protective earth system using a low-impedance conductor. A secure and reliable ground connection is essential for operator safety and electromagnetic compatibility (EMC).\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Verify that the supply voltage (115-230V AC) matches the equipment rating. Connect the provided mains cable to a properly fused and protected power source. Ensure power cables are routed separately from high-noise signal or high-voltage lines.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eVentilation and Clearance:\u003c\/strong\u003e Ensure adequate ventilation clearance around the rear of the unit to allow for proper heat dissipation. Do not block any ventilation openings. Operating the unit in an environment with excessive ambient temperature can reduce its lifespan and reliability.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSystem Startup:\u003c\/strong\u003e After all connections are secure, re-apply power to the cabinet. The Panel PC will boot into the pre-installed Windows 2000 operating system. Proceed with application-specific software installation and network configuration.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715806196075,"sku":"6AV7722-2BB10-0AD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7722-2bb10-0ad0-20lw5bnkxbd_b2743720-b25c-4654-811b-72f8b62634a3.jpg?v=1767071293","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7722-2bb10-0ad0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}