{"product_id":"siemens-6av7725-3bc40-0ad0-simatic-panel-pc-670","title":"Siemens 6AV7725-3BC40-0AD0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 16px;\"\u003eThis is a Siemens 6AV7725-3BC40-0AD0, a standard configuration SIMATIC Panel PC 670 designed for industrial control and visualization applications. This unit is equipped with a \u003cstrong\u003e15.1-inch Color TFT display\u003c\/strong\u003e, a \u003cstrong\u003ePentium III 1.26 GHz processor\u003c\/strong\u003e, and \u003cstrong\u003e512 MB of SDRAM\u003c\/strong\u003e. For data storage, it includes an \u003cstrong\u003e80 GB EIDE hard drive\u003c\/strong\u003e and a \u003cstrong\u003eCD-RW\/DVD optical drive\u003c\/strong\u003e. The system is pre-installed with a multi-language version of Windows 2000 and is powered by a \u003cstrong\u003e115-230V AC\u003c\/strong\u003e supply, delivered via a European standard mains cable.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e15.1-inch Color TFT Display\u003c\/li\u003e\n    \u003cli\u003ePentium III 1.26 GHz Processor\u003c\/li\u003e\n    \u003cli\u003e512 MB SDRAM-133 (2x 256 MB configuration)\u003c\/li\u003e\n    \u003cli\u003e80 GB EIDE Hard Disk Drive (HDD)\u003c\/li\u003e\n    \u003cli\u003eIntegrated CD-RW \/ DVD combination drive\u003c\/li\u003e\n    \u003cli\u003ePre-installed with Windows 2000 (Multi-Language)\u003c\/li\u003e\n    \u003cli\u003eIntegrated 115-230V AC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eHuman-Machine Interface (HMI) for process control\u003c\/li\u003e\n    \u003cli\u003eData acquisition and logging systems\u003c\/li\u003e\n    \u003cli\u003eMachine-level visualization and operation\u003c\/li\u003e\n    \u003cli\u003eSupervisory control stations in manufacturing environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; border: 1px solid #e2e8f0; border-radius: 4px; margin-bottom: 24px;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"text-align: left; padding: 12px; border-bottom: 2px solid #e2e8f0; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"text-align: left; padding: 12px; border-bottom: 2px solid #e2e8f0; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003e6AV7725-3BC40-0AD0\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003ePanel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003ePentium III, 1.26 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003e512 MB SDRAM-133 (2x 256 MB)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003e80 GB HDD EIDE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eOptical Drive\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003eCD-RW \/ DVD\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eDisplay\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003e15.1 inch Color TFT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003eWindows 2000 (Multi-Language)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003e115-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eMains Cable\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003eEuropean Standard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003e12.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003e48.0 cm x 29.0 cm x 15.0 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003e85371091\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eCountry of Origin (Estimate)\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px;\"\u003eGermany\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e This equipment is intended for use by qualified personnel only. Disconnect all power sources and follow Lockout\/Tagout (LOTO) procedures before installation or maintenance. Failure to de-energize the system can result in severe electrical shock, injury, or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003ePrepare Enclosure:\u003c\/strong\u003e Ensure the panel cutout dimensions match the PC 670's mounting requirements. The enclosure must provide adequate protection against environmental factors (dust, moisture) and ensure proper ventilation to prevent overheating.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the prepared cutout from the front. Secure it evenly using all provided mounting clamps. Do not overtighten the clamps, as this can damage the bezel or the enclosure.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect the chassis ground terminal on the rear of the Panel PC to the main protective earth (PE) busbar of the control cabinet. Use a low-impedance conductor of appropriate gauge. This is critical for both safety and noise immunity.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect Power:\u003c\/strong\u003e With the main power source de-energized, connect the provided European mains cable to the AC power inlet on the Panel PC. Ensure the source voltage (115-230V AC) is within the specified range for the unit.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect all required interface cables (e.g., Ethernet, USB, serial) to their respective ports. Ensure proper cable routing and strain relief to prevent accidental disconnection or damage.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections are secure and correct, remove LOTO devices and apply power to the cabinet. The Panel PC should boot into the pre-installed Windows 2000 operating system.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715867013483,"sku":"6AV7725-3BC40-0AD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7725-3bc40-0ad0-22tlqxqkc5g_68d067df-09f2-438d-b3e4-61a2f6b2462e.jpg?v=1767073249","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7725-3bc40-0ad0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}