{"product_id":"siemens-6av7822-0aa00-2ac0-simatic-panel-pc-577","title":"Siemens 6AV7822-0AA00-2AC0 SIMATIC Panel PC 577","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 16px;\"\u003eThis is a Siemens 6AV7822-0AA00-2AC0 SIMATIC Panel PC 577, an integrated industrial computer and human-machine interface (HMI). It is equipped with a \u003cstrong\u003e15-inch touch display\u003c\/strong\u003e, a \u003cstrong\u003eCeleron P4 2.0 GHz processor\u003c\/strong\u003e, and \u003cstrong\u003e256 MB of DDR400 SDRAM\u003c\/strong\u003e. This unit includes a DVD+-R\/RW optical drive for data transfer and software installation and comes pre-loaded with a multi-language version of Windows XP Professional SP1. Please note this model is considered an obsolete part in the product lifecycle.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e15-inch color touch-screen display for operator control and visualization.\u003c\/li\u003e\n  \u003cli\u003ePowered by an Intel Celeron P4 processor running at 2.0 GHz.\u003c\/li\u003e\n  \u003cli\u003eIncludes 256 MB of DDR400 SDRAM system memory.\u003c\/li\u003e\n  \u003cli\u003eFeatures an integrated DVD+-R\/RW optical drive.\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows XP Professional SP1 (MUI).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProcess visualization and control systems.\u003c\/li\u003e\n  \u003cli\u003eMachine-level data acquisition and logging.\u003c\/li\u003e\n  \u003cli\u003eFactory automation and assembly line monitoring.\u003c\/li\u003e\n  \u003cli\u003eLegacy system integration requiring a Windows XP environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSIMATIC Panel PC 577\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6AV7822-0AA00-2AC0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e15-inch Touch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProcessor (CPU)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCeleron P4 2.0 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e256 MB DDR400 SDRAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eDVD+-R\/RW Burner\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eWindows XP Professional SP1 MUI (EN, DE, FR, IT, SP, JP, CHN, KOR)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e15.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSiemens AG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e64.0 x 64.0 x 42.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px 16px; margin-bottom: 24px; background-color: #fff5f5; border-left: 4px solid #c53030;\"\u003e\n  \u003cp style=\"color: #c53030; font-weight: bold; margin: 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #2d3748; margin: 8px 0 0 0;\"\u003eThis equipment must be installed, operated, and maintained by qualified personnel only. Disconnect all power sources before installation or servicing to prevent electric shock and equipment damage. The panel's weight requires adequate structural support; verify the enclosure or mounting surface can safely bear the load.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; flex-shrink: 0; width: 24px; height: 24px; margin-right: 12px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; font-size: 14px;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003ePrepare Mounting Location:\u003c\/strong\u003e Ensure the panel cutout in the enclosure is precise and free of burrs. Verify that minimum clearance requirements for ventilation around the unit are met to prevent overheating.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; flex-shrink: 0; width: 24px; height: 24px; margin-right: 12px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; font-size: 14px;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to the specified torque to ensure a proper seal against the enclosure gasket.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; flex-shrink: 0; width: 24px; height: 24px; margin-right: 12px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; font-size: 14px;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003eConnect Protective Earth (PE):\u003c\/strong\u003e Connect the chassis to the main protective earth conductor of the cabinet using a low-impedance connection. This is critical for operator safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; flex-shrink: 0; width: 24px; height: 24px; margin-right: 12px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; font-size: 14px;\"\u003e4\u003c\/span\u003e\n    \u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003eConnect Power and Interfaces:\u003c\/strong\u003e Connect the DC or AC power supply as specified for the unit. Connect all communication and I\/O cables, ensuring proper shielding and grounding practices are followed to minimize electromagnetic interference (EMI).\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; flex-shrink: 0; width: 24px; height: 24px; margin-right: 12px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; font-size: 14px;\"\u003e5\u003c\/span\u003e\n    \u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003ePower-Up and Commission:\u003c\/strong\u003e After verifying all connections, re-apply power to the system. The Panel PC should boot into the pre-installed operating system. Proceed with application software installation and system configuration.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715847123307,"sku":"6AV7822-0AA00-2AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7822-0aa00-2ac0-ayx14dekztb_bad1dc05-3a28-47fb-b46b-7f72294c8560.jpg?v=1767072503","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7822-0aa00-2ac0-simatic-panel-pc-577","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}