{"product_id":"siemens-6av7872-0aa20-1ab0-simatic-panel-pc-677b","title":"Siemens 6AV7872-0AA20-1AB0 SIMATIC Panel PC 677B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6AV7872-0AA20-1AB0\u003c\/strong\u003e is a SIMATIC Panel PC 677B designed for industrial applications requiring a robust human-machine interface and computing platform. This unit features a 15-inch touch display with a resolution of 1024 x 768 pixels, providing clear visualization and intuitive operation. It is powered by a Celeron M440 processor operating at 1.86 GHz, complemented by 1 GB of DDR2 RAM and a 160 GB SATA 3.5\" hard disk drive. Connectivity options include two 10\/100\/1000 Mbit\/s Ethernet ports, four USB V2.0 ports (including a front-side USB interface), and one serial (COM1) port. The Panel PC also integrates PROFIBUS\/MP for fieldbus communication and includes 2 MB of buffered SRAM. It operates on a 24 V DC power supply and comes pre-installed with Windows 2000 Professional MUI, supporting multiple languages.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e15-inch Touch Display with 1024 x 768 Resolution\u003c\/li\u003e\n  \u003cli\u003eIntegrated Celeron M440\/1.86 GHz Processor\u003c\/li\u003e\n  \u003cli\u003e1 GB DDR2 RAM and 160 GB SATA 3.5\" HDD\u003c\/li\u003e\n  \u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet Interfaces\u003c\/li\u003e\n  \u003cli\u003eFour USB V2.0 Ports (including front-side access)\u003c\/li\u003e\n  \u003cli\u003eOne Serial (COM1) Port\u003c\/li\u003e\n  \u003cli\u003ePROFIBUS\/MP Communication Interface\u003c\/li\u003e\n  \u003cli\u003e2x PCI Expansion Slots\u003c\/li\u003e\n  \u003cli\u003e2 MB Buffered SRAM\u003c\/li\u003e\n  \u003cli\u003e24 V DC Power Supply\u003c\/li\u003e\n  \u003cli\u003ePre-installed Windows 2000 Professional MUI\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens SIMATIC Panel PC 677B is suitable for a wide range of industrial automation tasks, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMachine operation and control\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and monitoring\u003c\/li\u003e\n  \u003cli\u003eData acquisition and logging\u003c\/li\u003e\n  \u003cli\u003eIndustrial HMI (Human-Machine Interface) systems\u003c\/li\u003e\n  \u003cli\u003eEmbedded control applications\u003c\/li\u003e\n  \u003cli\u003eFactory automation and manufacturing execution systems (MES)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Panel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC677B\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCeleron M440\/1.86 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor Cache\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 MB SLC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 GB DDR2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e160 GB SATA HDD 3.5\"\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout optical drive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15\" Touch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024 x 768\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x USB V2.0 (with front-side interface)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x (COM1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x PCI\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFieldbus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBuffered SRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows 2000 Professional MUI (de,en,fr,es,it,ja,zh,ko)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e60.00 x 56.50 x 30.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e84714100\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5D992\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEthernet: 2x RJ45 (10\/100\/1000 Mbit\/s)\u003c\/li\u003e\n  \u003cli\u003eUSB: 4x USB V2.0 (Type A, including front-side)\u003c\/li\u003e\n  \u003cli\u003eSerial: 1x RS-232 (COM1)\u003c\/li\u003e\n  \u003cli\u003eFieldbus: PROFIBUS\/MP\u003c\/li\u003e\n  \u003cli\u003ePower: 24 V DC terminal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the control cabinet or system is disconnected before beginning installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the Panel PC into the designated panel cutout or mounting frame according to the system's mechanical specifications. Ensure adequate ventilation space around the unit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated terminals, observing correct polarity. Verify the power source meets the specified voltage and current requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEthernet Connections:\u003c\/strong\u003e Connect Ethernet cables to the RJ45 ports for network communication. Use shielded cables in industrial environments to reduce noise.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUSB and Serial Connections:\u003c\/strong\u003e Connect peripheral devices (e.g., keyboard, mouse, barcode scanner, external serial devices) to the appropriate USB V2.0 and COM1 ports.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePROFIBUS\/MP Connection:\u003c\/strong\u003e If utilizing PROFIBUS\/MP, connect the bus cable to the designated interface. Ensure proper termination of the bus segment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Route all cables to prevent strain, interference, and damage. Secure cables with appropriate ties or conduits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRe-energize and Test:\u003c\/strong\u003e After all connections are made and verified, re-apply power to the system and perform functional tests to ensure proper operation of the Panel PC and connected peripherals.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716243878251,"sku":"6AV7872-0AA20-1AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7872-0aa20-1ab0-qjriqh1lo0k_c5461af4-0df4-45dc-93aa-a37d9ed78ac0.jpg?v=1767079925","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7872-0aa20-1ab0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}