{"product_id":"siemens-6av7872-0bd20-0ac0-simatic-panel-pc-677b","title":"Siemens 6AV7872-0BD20-0AC0 SIMATIC Panel PC 677B","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n    \u003cp\u003eThis product is a Siemens 6AV7872-0BD20-0AC0, a SIMATIC Panel PC 677B designed for industrial human-machine interface (HMI) and control applications. It features a \u003cstrong\u003e15-inch touch display\u003c\/strong\u003e with a resolution of \u003cstrong\u003e1024 x 768 pixels\u003c\/strong\u003e and is powered by an Intel \u003cstrong\u003eCore 2 Duo T5500 processor\u003c\/strong\u003e. The system is configured with \u003cstrong\u003e1 GB of DDR2 RAM\u003c\/strong\u003e and a \u003cstrong\u003e160 GB SATA hard disk drive\u003c\/strong\u003e. For connectivity, it includes dual Gigabit Ethernet ports, multiple USB 2.0 interfaces, a serial port, and an integrated PROFIBUS\/MPI interface. This unit is pre-installed with the Windows XP Professional Multi-language User Interface operating system and is powered by a 110\/230 V AC supply.\u003c\/p\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eFeatures\u003c\/h3\u003e\n    \u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003e15-inch touch screen display with 1024 x 768 resolution\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIntel Core 2 Duo T5500 processor at 1.66 GHz\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003e1 GB DDR2 RAM and 160 GB 3.5-inch SATA HDD\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIntegrated PROFIBUS\/MPI communication interface\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eDual 10\/100\/1000 Mbit\/s Ethernet ports\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eFront-side USB port for convenient access\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003ePre-installed Windows XP Professional MUI\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003e110\/230 V AC power supply with NAMUR configuration\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n    \u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eMachine-level visualization and control\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eProcess monitoring and data acquisition systems\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIndustrial SCADA client stations\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eFactory automation and plant floor operations\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto;\"\u003e\n        \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n            \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003eCategory\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px; background-color: #f7fafc; font-weight: bold;\"\u003eSpecification\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eDisplay\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e15-inch Touch Screen, Membrane\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003eIntel Core 2 Duo T5500, 1.66 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eProcessor Cache\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e2 MB SLC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e1 GB DDR2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e160 GB SATA HDD, 3.5-inch\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eOptical Drive\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003eNot included\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003eWindows XP Professional MUI (de, en, fr, es, it, ja, zh, ko)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eInterfaces\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e2x 10\/100\/1000 Mbit\/s Ethernet; 4x USB 2.0 (rear); 1x USB (front); 1x Serial (COM1); 1x PROFIBUS\/MPI\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eExpansion Slots\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e1x PCIe x4, 1x PCI\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eBuffered SRAM\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e2 MB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e110\/230 V AC, with NAMUR\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eIncluded Accessories\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003ePower supply cable (Europe)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eProduct Status\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e4.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e45 x 35 x 20 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003e85371091\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px 8px;\"\u003eN\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n    \u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 16px;\"\u003e\n        \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment and follow Lockout\/Tagout (LOTO) procedures before installation can result in severe injury or death.\n    \u003c\/div\u003e\n    \u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n        \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n            \u003cspan\u003eEnsure the main power supply to the control cabinet or mounting location is completely de-energized and locked out. Verify the absence of voltage before proceeding.\u003c\/span\u003e\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n            \u003cspan\u003ePrepare the panel cutout according to the device's mechanical specifications. Ensure the mounting surface is clean, flat, and can support the weight of the unit.\u003c\/span\u003e\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n            \u003cspan\u003eInsert the Panel PC into the cutout and secure it using the provided mounting clamps. Tighten the clamps evenly in a cross pattern to ensure a uniform seal against the panel.\u003c\/span\u003e\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n            \u003cspan\u003eConnect a dedicated protective earth (PE) conductor to the designated grounding terminal on the Panel PC chassis. This connection is critical for electrical safety and noise immunity.\u003c\/span\u003e\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n            \u003cspan\u003eConnect all required communication cables, including Ethernet, USB, serial, and PROFIBUS. Ensure proper cable shielding and routing to minimize electromagnetic interference.\u003c\/span\u003e\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n            \u003cspan\u003eConnect the 110\/230 V AC power supply cable to the unit's power input terminal. Ensure the source voltage matches the device's rating.\u003c\/span\u003e\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n            \u003cspan\u003eAfter verifying all connections, remove the lockout\/tagout devices and re-energize the main power supply. Power on the Panel PC and verify correct system startup.\u003c\/span\u003e\n        \u003c\/li\u003e\n    \u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715864457579,"sku":"6AV7872-0BD20-0AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/simatic-panel-pc677b-15-quot-touc-2zcngweijuy_fabb9b98-fa84-46dc-b577-a1b851cfa292.jpg?v=1767073142","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7872-0bd20-0ac0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}