{"product_id":"siemens-6av7881-4aa00-0aa0-simatic-ipc277d-nanopanel-pc","title":"Siemens 6AV7881-4AA00-0AA0 SIMATIC IPC277D Nanopanel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 20px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6AV7881-4AA00-0AA0 SIMATIC IPC277D Nanopanel PC, an industrial-grade human-machine interface (HMI) designed for demanding automation environments. It features a \u003cstrong\u003e15-inch TFT touchscreen\u003c\/strong\u003e display, an Intel \u003cstrong\u003eAtom E640 (1.0 GHz)\u003c\/strong\u003e processor, and \u003cstrong\u003e1 GB of RAM\u003c\/strong\u003e. This specific configuration is supplied without a pre-installed operating system or SIMATIC software, offering flexibility for custom application deployment. The unit is powered by a standard \u003cstrong\u003e24 V DC\u003c\/strong\u003e supply and provides extensive connectivity through dual Gigabit Ethernet ports and multiple USB interfaces.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e15-inch TFT resistive touchscreen display\u003c\/li\u003e\n  \u003cli\u003eIntel Atom E640 processor operating at 1.0 GHz\u003c\/li\u003e\n  \u003cli\u003e1 GB of integrated RAM\u003c\/li\u003e\n  \u003cli\u003eDual 10\/100\/1000 Mbps RJ45 Ethernet ports for network redundancy or separation\u003c\/li\u003e\n  \u003cli\u003eOne front-accessible USB port for convenient data transfer\u003c\/li\u003e\n  \u003cli\u003eThree rear high-current USB 2.0 ports\u003c\/li\u003e\n  \u003cli\u003eOne serial COM1 interface\u003c\/li\u003e\n  \u003cli\u003eIntegrated CompactFlash (CF) card slot for storage\u003c\/li\u003e\n  \u003cli\u003eOperates on a 24 V DC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eMachine-level HMI and process visualization\u003c\/li\u003e\n  \u003cli\u003eData acquisition and logging systems\u003c\/li\u003e\n  \u003cli\u003eControl and monitoring in manufacturing and process industries\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and facility management interfaces\u003c\/li\u003e\n  \u003cli\u003eEmbedded control applications requiring a graphical user interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n  \u003cthead style=\"background-color: #f2f2f2;\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"padding: 10px; text-align: left; border-bottom: 1px solid #ccc; font-weight: bold; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; text-align: left; border-bottom: 1px solid #ccc; font-weight: bold; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e6AV7881-4AA00-0AA0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eSIMATIC IPC277D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eNanopanel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eDisplay\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e15-inch Touch TFT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eProcessor\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eIntel Atom E640 (1.0 GHz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eMemory (RAM)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e1 GB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eStorage\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eCompactFlash Slot (Card not included)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eEthernet Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e2x 10\/100\/1000 Mbps RJ45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eUSB Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e1x Front USB, 3x Rear USB 2.0 (High Current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eSerial Port\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e1x COM1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003ePower Supply Input\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eOperating System\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eNot included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003ePre-installed Software\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eNone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e4.55 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e60.5 x 41.5 x 6.5 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eECCN\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003e5A992\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eGermany (Contact us for confirmation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border-bottom: 1px solid #ccc;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical hazard. Disconnect and lock out all power sources before installation or maintenance. Installation must be performed by qualified personnel in accordance with all applicable electrical codes and regulations. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003ePanel Cutout:\u003c\/strong\u003e Prepare the enclosure by creating a panel cutout according to the dimensions specified in the device's mechanical drawings. Ensure all edges are smooth and free of burrs to guarantee a proper seal.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the specified torque to ensure consistent gasket compression and maintain the IP rating.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional earth (FE) terminal on the device chassis to the enclosure's main protective earth ground using a low-impedance, short-gauge wire. A reliable ground connection is essential for noise immunity and safety.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect a stable, filtered 24 V DC power source to the designated power supply terminals. Verify correct polarity (+\/-) before energizing the unit. Use appropriately sized wiring for the current draw.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eInterface Cabling:\u003c\/strong\u003e Connect Ethernet, USB, and serial cables as required. Route data cables separately from high-voltage power lines to prevent electromagnetic interference. Ensure all connectors are fully seated and secured.\u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716688965995,"sku":"6AV7881-4AA00-0AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7881-4aa00-0aa0-o0tkaf1swqc_9fab603a-6b40-4c59-80b6-c74ab637cc85.jpg?v=1767088001","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7881-4aa00-0aa0-simatic-ipc277d-nanopanel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}