{"product_id":"siemens-6av7885-2ak20-3ba8-simatic-hmi-ipc-577c-panel-pc","title":"Siemens 6AV7885-2AK20-3BA8 SIMATIC HMI IPC 577C Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis device is a Siemens 6AV7885-2AK20-3BA8 SIMATIC HMI IPC 577C, a robust Panel PC designed for human-machine interface (HMI) applications in industrial environments. It features a \u003cstrong\u003e15-inch touch display\u003c\/strong\u003e, an Intel \u003cstrong\u003eCore 2 Duo 1.86 GHz processor\u003c\/strong\u003e, and \u003cstrong\u003e2 GB of DDR3 RAM\u003c\/strong\u003e. The system is configured with a \u003cstrong\u003e4 GB CompactFlash card\u003c\/strong\u003e as the primary storage medium, which comes pre-installed with the \u003cstrong\u003eWindows Embedded Standard 2009\u003c\/strong\u003e operating system. Connectivity is provided through dual Gigabit Ethernet ports, an integrated PROFINET interface, and multiple USB ports. The unit operates on a \u003cstrong\u003e24 V DC power supply\u003c\/strong\u003e and includes a PCI slot for hardware expansion.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n    \u003cli\u003e15-inch integrated touch screen display\u003c\/li\u003e\n    \u003cli\u003eIntel Core 2 Duo processor operating at 1.86 GHz\u003c\/li\u003e\n    \u003cli\u003e2 GB of DDR3 system memory\u003c\/li\u003e\n    \u003cli\u003e4 GB CompactFlash card for primary storage\u003c\/li\u003e\n    \u003cli\u003eWindows Embedded Standard 2009 operating system pre-installed\u003c\/li\u003e\n    \u003cli\u003eIntegrated PROFINET (IE) communication interface\u003c\/li\u003e\n    \u003cli\u003eDual 1 Gbit (10\/100\/1000) Ethernet ports\u003c\/li\u003e\n    \u003cli\u003eOne available PCI expansion slot\u003c\/li\u003e\n    \u003cli\u003eOperates on a 24 V DC power source\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n    \u003cli\u003eMachine-level control and visualization\u003c\/li\u003e\n    \u003cli\u003eProcess monitoring and data acquisition systems\u003c\/li\u003e\n    \u003cli\u003eOperator control stations in manufacturing\u003c\/li\u003e\n    \u003cli\u003eFactory and process automation control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC HMI IPC 577C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e15-inch Touch Display\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIntel Core 2 Duo, 1.86 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2 GB DDR3\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePrimary Storage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4 GB CompactFlash (CF) Card\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSecondary Storage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eNot equipped\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWindows Embedded Standard 2009 (pre-installed)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEthernet Ports\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2x 1 Gbit (10\/100\/1000 Mbps)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIndustrial Communication\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET (IE)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eUSB Ports\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4x USB (Rear), 1x USB (Front)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eExpansion Slots\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1x PCI slot\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e64.00 x 64.00 x 42.00 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e15.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n    \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: RISK OF ELECTRIC SHOCK\u003c\/p\u003e\n    \u003cp style=\"margin-bottom: 0;\"\u003eDisconnect all power sources and follow Lockout\/Tagout (LOTO) procedures before installation or servicing. This equipment must be installed in an enclosure that provides protection against direct contact. Installation must be performed by qualified personnel only.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure the main power to the control cabinet or enclosure is completely shut off and locked out before beginning any work. Verify the absence of voltage.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003ePrepare Panel Cutout:\u003c\/strong\u003e Verify that the panel cutout dimensions match the requirements for the IPC 577C. Ensure the mounting surface is clean, flat, and free of debris to guarantee a proper seal.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front of the panel. Secure it from the rear using the provided mounting clamps, tightening them evenly to the specified torque to ensure environmental sealing.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect Power:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated power terminal. Strictly observe correct polarity (+\/-) to prevent damage to the unit. Use appropriately sized conductors for the load.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect the chassis of the Panel PC to the protective earth (PE) ground of the control cabinet using a low-impedance conductor. A reliable ground connection is essential for safety and noise immunity.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eConnect Peripherals and Networks:\u003c\/strong\u003e Connect Ethernet, PROFINET, and any required USB devices. Ensure all cables are properly routed and secured to prevent strain on the connectors.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eFinal Check and Power-Up:\u003c\/strong\u003e After all connections are made and verified, close the control cabinet door. Remove the lockout\/tagout device and re-energize the system. Verify that the Panel PC boots correctly.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715811045739,"sku":"6AV7885-2AK20-3BA8","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7885-2ak20-3ba8-abp4m2r1vou_88f76f42-33b5-4032-9e3b-b26e9ec1507c.jpg?v=1767071482","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6av7885-2ak20-3ba8-simatic-hmi-ipc-577c-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}