{"product_id":"siemens-6es7134-6jd00-0ca1-simatic-et-200sp-analog-input-module","title":"Siemens 6ES7134-6JD00-0CA1 SIMATIC ET 200SP Analog Input Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe Siemens 6ES7134-6JD00-0CA1 is a 4-channel analog input module for the SIMATIC ET 200SP distributed I\/O system. It is engineered to interface with temperature sensors, providing high-precision data acquisition for both Resistance Temperature Detectors (RTDs) and various thermocouple types. This module features a \u003cstrong\u003e16-bit resolution\u003c\/strong\u003e and a measurement accuracy of \u003cstrong\u003e±0.1%\u003c\/strong\u003e, ensuring reliable process values for monitoring and control. Integrated channel-level diagnostics and flexible wiring options make it suitable for demanding industrial temperature measurement applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eProvides four analog inputs for temperature measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSupports both Resistance Temperature Detector (RTD) and thermocouple sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eHigh-resolution 16-bit analog-to-digital conversion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eOffers a measurement accuracy of ±0.1%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eFlexible sensor wiring with support for 2-, 3-, and 4-wire RTD connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eIncludes channel-specific diagnostics for detecting wire breaks and sensor failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eDesigned for use with SIMATIC ET 200SP Base Units type A0 or A1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eIdentified by color code CC00 for easy system integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eProcess manufacturing and automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eChemical and pharmaceutical production\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003ePower generation and utilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eFood and beverage processing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eWater and wastewater treatment plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6ES7134-6JD00-0CA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModule Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSupported Sensor Types\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eResistance Temperature Detectors (RTD), Thermocouples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRequired Base Unit\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eType A0 or A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eColor Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCC00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCondition\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eHS Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2.5 cm x 5.1 cm x 83.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 16px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Installation must be performed by qualified personnel only. Disconnect and lock out all power sources before installation or maintenance to prevent electric shock and equipment damage. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n\u003cli style=\"margin-bottom: 12px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold; content: counter(step-counter); counter-increment: step-counter;\"\u003e1\u003c\/span\u003e\n\u003cstrong\u003ePrepare for Installation:\u003c\/strong\u003e Verify the module part number matches the project specification. Ensure the corresponding Base Unit (Type A0 or A1) is available and correctly installed on the DIN rail within the control panel.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold; content: counter(step-counter); counter-increment: step-counter;\"\u003e2\u003c\/span\u003e\n\u003cstrong\u003eMount the Module:\u003c\/strong\u003e Align the module with the Base Unit, ensuring the coding elements match. Push the module firmly into the Base Unit until it clicks securely into place. The module should be flush with adjacent ET 200SP modules.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold; content: counter(step-counter); counter-increment: step-counter;\"\u003e3\u003c\/span\u003e\n\u003cstrong\u003eConnect Sensor Wiring:\u003c\/strong\u003e Strip sensor cable insulation to the specified length. Use appropriate shielded, twisted-pair cabling for all analog signals to minimize noise interference. Connect the sensor wires to the terminals of the Base Unit according to the 2-, 3-, or 4-wire configuration required for your sensor type.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold; content: counter(step-counter); counter-increment: step-counter;\"\u003e4\u003c\/span\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Connect the cable shield to the functional earth (FE) terminal on the Base Unit. Ensure a low-impedance path to the main panel ground to provide effective noise immunity. The shield should be grounded at the panel end only.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold; content: counter(step-counter); counter-increment: step-counter;\"\u003e5\u003c\/span\u003e\n\u003cstrong\u003eSystem Power-Up and Verification:\u003c\/strong\u003e After all connections are verified, remove the lockout\/tagout and restore power to the system. In the PLC programming software, configure the module channels for the correct sensor type and measurement range. Verify that the module's diagnostic LEDs indicate normal operation and that sensor readings are stable and accurate.\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695211999595,"sku":"6ES7134-6JD00-0CA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6es7134-6jd00-0ca1-analog-input-module-5ahv42tmgyc_eb084a36-e440-416d-a75e-b1dfba71a484.jpg?v=1766130858","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6es7134-6jd00-0ca1-simatic-et-200sp-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}