{"product_id":"siemens-6es7157-0ag82-0xa0-active-field-distributor-afd8","title":"Siemens 6ES7157-0AG82-0XA0 Distributeur de terrain actif AFD8","description":"\u003cp\u003eThe \u003cstrong\u003e6ES7157-0AG82-0XA0\u003c\/strong\u003e is an \u003cstrong\u003eActive Field Distributor (AFD8)\u003c\/strong\u003e designed for \u003cstrong\u003ePROFIBUS PA\u003c\/strong\u003e and \u003cstrong\u003eFoundation Fieldbus H1\u003c\/strong\u003e network architectures. This field device provides eight short-circuit-proof spur lines, ensuring that a fault on one branch does not compromise the entire bus segment. It features advanced bounce protection logic and supports automatic bus termination for both line and ring topologies. Engineered for high reliability in harsh industrial conditions, the device offers an extended temperature range and an IP66 degree of protection, making it suitable for demanding field-level automation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAFD8 Configuration:\u003c\/strong\u003e Supports 8 short-circuit-proof spur lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Compatibility:\u003c\/strong\u003e Designed for PROFIBUS PA and Foundation Fieldbus H1 systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Reliability:\u003c\/strong\u003e Includes bounce protection logic to ensure stable data transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopology Flexibility:\u003c\/strong\u003e Supports automatic bus termination for both line and ring network structures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Design:\u003c\/strong\u003e IP66-rated housing for high-performance operation in industrial environments with extended temperature capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFieldbus segment distribution in process automation.\u003c\/li\u003e\n\u003cli\u003eHazardous and non-hazardous area network infrastructure.\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O systems requiring high fault tolerance.\u003c\/li\u003e\n\u003cli\u003eIndustrial process plants utilizing PROFIBUS PA or Foundation Fieldbus H1 communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSIMATIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eActive Field Distributor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAFD8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e16-32V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpur Lines\u003c\/td\u003e\n\u003ctd\u003e8 (Short-circuit-proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology Support\u003c\/td\u003e\n\u003ctd\u003eLine and Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e36.00 cm x 8.30 cm x 12.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECCN\u003c\/td\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the device is mounted in a location that allows for proper cable routing and access for maintenance while adhering to the IP66 ingress protection requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e Utilize the automatic bus termination feature for ring or line configurations; ensure the topology is wired according to the specific Fieldbus standards to enable this functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use certified fieldbus cabling and cable glands that match the IP66 rating to prevent moisture or dust ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowering:\u003c\/strong\u003e Verify that the supply voltage provided to the distributor is within the 16-32V DC range to ensure stable operation of the active components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Management:\u003c\/strong\u003e Ensure the short-circuit protection is not bypassed, as this is critical for maintaining network integrity in the event of spur line issues.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716783501675,"sku":"6ES7157-0AG82-0XA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7157-0ag82-0xa0-yusv5mbayae_2f4d6867-2ddd-4047-af58-a62c2dd10476.jpg?v=1767089639","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6es7157-0ag82-0xa0-active-field-distributor-afd8","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}