{"product_id":"siemens-6es7647-5ag04-3ax0-simatic-box-pc-620-industrial-pc","title":"Siemens 6ES7647-5AG04-3AX0 SIMATIC BOX PC 620 Industrial PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7647-5AG04-3AX0 is a SIMATIC BOX PC 620 designed for industrial control and visualization applications. This unit is equipped with a \u003cstrong\u003eCeleron 566 MHz\u003c\/strong\u003e processor, \u003cstrong\u003e64 MB of SDRAM-133\u003c\/strong\u003e, and a \u003cstrong\u003e40 GB EIDE hard drive\u003c\/strong\u003e. Connectivity is provided through onboard 10\/100 Mbit\/s Ethernet, a \u003cstrong\u003ePROFIBUS\/MPI interface\u003c\/strong\u003e operating at 12 Mbit\/s, two USB ports, and a TTY port. The system includes integrated AGP graphics and features for industrial reliability such as a watchdog timer and temperature monitoring. It is powered by a 110\/230V AC industrial power supply and comes pre-installed with MS-DOS 6.22.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eProcessor: Celeron 566 MHz with 128 KB SLC\u003c\/li\u003e\n\u003cli\u003eMemory: 64 MB SDRAM-133 RAM\u003c\/li\u003e\n\u003cli\u003eStorage: 40 GB EIDE Hard Disk Drive (HDD)\u003c\/li\u003e\n\u003cli\u003eGraphics: Onboard AGP with configurable 8\/16\/32 MB memory\u003c\/li\u003e\n\u003cli\u003eFieldbus Interface: PROFIBUS\/MPI at 12 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eNetwork: 10\/100 Mbit\/s Ethernet (RJ45)\u003c\/li\u003e\n\u003cli\u003eExpansion Slots: 1x PCI, 1x ISA\/PCI, 1x PC Card (PCMCIA Type 3)\u003c\/li\u003e\n\u003cli\u003eSystem Monitoring: Integrated watchdog timer and temperature monitoring\u003c\/li\u003e\n\u003cli\u003ePower Supply: 110\/230V AC industrial power pack with NAMUR\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eHuman-Machine Interface (HMI) systems\u003c\/li\u003e\n\u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes\u003c\/li\u003e\n\u003cli\u003eIndustrial data logging and archiving\u003c\/li\u003e\n\u003cli\u003eMachine-level control and automation tasks\u003c\/li\u003e\n\u003cli\u003eProcess visualization and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; background-color: #f7fafc; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; background-color: #f7fafc; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSIMATIC BOX PC 620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eCeleron 566 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProcessor Cache\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e128 KB SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e64 MB SDRAM-133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e40 GB HDD EIDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eGraphics\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eOnboard AGP, 8\/16\/32 MB configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eEthernet Port\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1x 10\/100 Mbit\/s (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eFieldbus Port\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePROFIBUS\/MPI, 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSerial Port\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eTTY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eUSB Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1x PCI, 1x ISA\/PCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eCard Slot\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePC Card (PCMCIA Type 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e110\/230V AC, 85 A Industry Power Pack with NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePre-installed OS\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eMS-DOS 6.22 (English)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eFDD Adapter, UK Power Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e7.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e45.0 x 47.5 x 27.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect and lock out all power sources before installation or maintenance. Work must be performed by qualified personnel only. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSite Preparation:\u003c\/strong\u003e Ensure the mounting location provides adequate clearance for ventilation on all sides of the PC chassis. The environment must be within the specified operating temperature range and free from excessive vibration or contaminants.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e Securely fasten the Box PC to the panel or mounting surface using all provided mounting points. Verify the unit is level and stable.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis protective earth (PE) terminal to the main panel ground using a low-impedance conductor. A reliable ground connection is essential for safety and noise immunity.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e With the main power off, connect the provided AC power cable to the unit's power inlet and to a properly rated and protected AC power source. Ensure the source voltage matches the 110\/230V AC rating.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eI\/O Connections:\u003c\/strong\u003e Connect PROFIBUS\/MPI, Ethernet, USB, and any other required peripheral cables. Ensure all connectors are fully seated and secured. Use shielded cables for all data communication lines.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFinal Checks and Power-Up:\u003c\/strong\u003e Close the control panel door. Restore power to the circuit and switch on the PC. Verify that the system boots into the MS-DOS operating system and that all status indicators are normal.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716284182891,"sku":"6ES7647-5AG04-3AX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-5ag04-3ax0-xysnsud3v4d_225a29fa-aab3-417c-a921-41605ea134d1.jpg?v=1767080289","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6es7647-5ag04-3ax0-simatic-box-pc-620-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}