{"product_id":"siemens-6es7647-6bd30-0ab0-simatic-box-pc-627b-industrial-pc","title":"Siemens 6ES7647-6BD30-0AB0 SIMATIC BOX PC 627B Industrial PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7647-6BD30-0AB0 is an industrial computer from the SIMATIC BOX PC 627B series, engineered for reliable operation in demanding automation environments. This unit is powered by an \u003cstrong\u003eIntel Core 2 Duo T5500 processor\u003c\/strong\u003e and is equipped with \u003cstrong\u003e2 GB of DDR2 RAM\u003c\/strong\u003e, providing a stable platform for control and visualization tasks. It features a \u003cstrong\u003e160 GB SATA hard drive\u003c\/strong\u003e and an onboard RAID controller for data integrity. Connectivity is handled by dual Gigabit Ethernet ports, four high-current USB 2.0 ports, and a serial COM port. The system includes integrated monitoring for watchdog, temperature, and fan status, and is pre-installed with Windows XP Professional SP2.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eProcessor: Intel Core 2 Duo T5500 (1.66 GHz, 2 MB L2 Cache)\u003c\/li\u003e\n  \u003cli\u003eMemory: 2 GB DDR2 667 SODIMM\u003c\/li\u003e\n  \u003cli\u003eStorage: 160 GB SATA Hard Disk Drive (HDD)\u003c\/li\u003e\n  \u003cli\u003eGraphics: Onboard controller with 128 MB shared memory\u003c\/li\u003e\n  \u003cli\u003eConnectivity: Dual 10\/100\/1000 Mbit\/s Ethernet ports\u003c\/li\u003e\n  \u003cli\u003eData Integrity: Onboard RAID controller\u003c\/li\u003e\n  \u003cli\u003eExpansion: Two free PCI slots\u003c\/li\u003e\n  \u003cli\u003eSystem Monitoring: Integrated watchdog, temperature, and fan supervision\u003c\/li\u003e\n  \u003cli\u003ePower Supply: 110\/230V AC industrial power supply with NAMUR compliance\u003c\/li\u003e\n  \u003cli\u003eOperating System: Windows XP Professional Multi-Language SP2 pre-installed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) systems\u003c\/li\u003e\n  \u003cli\u003eProcess control and data acquisition (SCADA)\u003c\/li\u003e\n  \u003cli\u003eData logging and archiving\u003c\/li\u003e\n  \u003cli\u003eGateway for industrial networks\u003c\/li\u003e\n  \u003cli\u003eMachine-level control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC BOX PC 627B\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd colspan=\"2\" style=\"background-color: #edf2f7; color: #1a365d; font-weight: bold; padding: 12px; border: 1px solid #e2e8f0;\"\u003eProcessing Unit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCPU\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eIntel Core 2 Duo T5500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eClock Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e1.66 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eL2 Cache\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e2 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eFront Side Bus (FSB)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e667 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd colspan=\"2\" style=\"background-color: #edf2f7; color: #1a365d; font-weight: bold; padding: 12px; border: 1px solid #e2e8f0;\"\u003eMemory and Storage\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e2 GB DDR2 667 SODIMM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eHard Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e160 GB HDD SATA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eRAID Controller\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOnboard\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eRemovable Media Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eFront-side CompactFlash (CF card not included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd colspan=\"2\" style=\"background-color: #edf2f7; color: #1a365d; font-weight: bold; padding: 12px; border: 1px solid #e2e8f0;\"\u003eInterfaces\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eEthernet\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e2 x 10\/100\/1000 Mbit\/s RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eUSB\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e4 x USB 2.0 (High Current)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSerial\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e1 x COM1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e2 x PCI (free)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd colspan=\"2\" style=\"background-color: #edf2f7; color: #1a365d; font-weight: bold; padding: 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e110\/230V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eIndustrial Power Supply with NAMUR\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePower Cable\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eEurope\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd colspan=\"2\" style=\"background-color: #edf2f7; color: #1a365d; font-weight: bold; padding: 12px; border: 1px solid #e2e8f0;\"\u003eSoftware\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eWindows XP Professional Multi-Language SP2 (DE, EN, FR, SP, IT)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd colspan=\"2\" style=\"background-color: #edf2f7; color: #1a365d; font-weight: bold; padding: 12px; border: 1px solid #e2e8f0;\"\u003eLogistics\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e45.0 x 47.5 x 27.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f7fafc;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e7.05 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff;\"\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. Failure to adhere to safety procedures can result in severe injury or equipment damage. Always de-energize and lock out\/tag out (LOTO) the main power supply before accessing the control cabinet.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before installation, disconnect all power sources to the industrial control panel. Verify the absence of voltage using a properly rated test instrument.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eVerify Clearances:\u003c\/strong\u003e Ensure adequate ventilation space around the PC chassis as specified by the manufacturer to prevent overheating. Do not block fan inlets or exhausts.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Mount the Box PC securely to a stable panel or chassis using all provided mounting points. Ensure the unit is level and cannot vibrate loose during operation.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eProtective Earth Connection:\u003c\/strong\u003e Connect the chassis ground terminal to the main panel's protective earth (PE) bus using a low-impedance conductor. This is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Power and I\/O:\u003c\/strong\u003e Connect the AC power supply cable. Route all communication and I\/O cables away from high-voltage lines to minimize electrical noise. Ensure all connectors are fully seated and secured.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eFinal Checks:\u003c\/strong\u003e Close the control cabinet door. Remove the lockout\/tagout device and re-energize the main supply. Power on the PC and verify correct system boot and operation.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716585550187,"sku":"6ES7647-6BD30-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-6bd30-0ab0-ifhmpj2qjyj_6eb5a164-2d6b-44e7-813b-4d48b52f1ed2.jpg?v=1767086217","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6es7647-6bd30-0ab0-simatic-box-pc-627b-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}