{"product_id":"siemens-6es7647-6ma12-0bc0-simatic-box-pc-840-v2-industrial-pc","title":"Siemens 6ES7647-6MA12-0BC0 SIMATIC BOX PC 840 V2 Industrial PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7647-6MA12-0BC0 is an industrial computer from the SIMATIC BOX PC 840 V2 series, designed for robust performance in demanding automation environments. This unit is equipped with a \u003cstrong\u003eCeleron 2.0 GHz processor\u003c\/strong\u003e, \u003cstrong\u003e256 MB of DDR SDRAM\u003c\/strong\u003e, and an \u003cstrong\u003e80 GB EIDE hard disk drive\u003c\/strong\u003e. It features a versatile set of expansion slots, including PCI and ISA, to accommodate various legacy and modern interface cards. Integrated monitoring functions such as a watchdog timer and temperature monitoring ensure operational reliability. The system is pre-installed with Windows NT 4.0 Workstation and includes an industrial-grade power supply unit compatible with 110\/230V AC inputs.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003ePowered by a Celeron 2.0 GHz processor with a 400 MHz Front Side Bus.\u003c\/li\u003e\n    \u003cli\u003eEquipped with 256 MB of DDR SDRAM for application processing.\u003c\/li\u003e\n    \u003cli\u003eIncludes an 80 GB EIDE Hard Disk Drive, a Floppy Disk Drive (FDD), and a DVD-ROM drive.\u003c\/li\u003e\n    \u003cli\u003eOnboard AGP graphics with 8\/16\/32 MB of shared memory.\u003c\/li\u003e\n    \u003cli\u003eFeatures a mix of expansion slots: 2x PCI, 2x ISA\/PCI, and 1x ISA.\u003c\/li\u003e\n    \u003cli\u003eIntegrated 10\/100 Mbit\/s Ethernet port for network connectivity.\u003c\/li\u003e\n    \u003cli\u003eTwo high-current USB ports for peripheral devices.\u003c\/li\u003e\n    \u003cli\u003eBuilt-in watchdog timer and temperature monitoring for system stability.\u003c\/li\u003e\n    \u003cli\u003eIndustrial power supply unit rated for 110\/230V AC with NAMUR compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eHuman-Machine Interface (HMI) and SCADA visualization stations.\u003c\/li\u003e\n    \u003cli\u003eData acquisition, logging, and archival systems.\u003c\/li\u003e\n    \u003cli\u003eIndustrial control and communication gateways.\u003c\/li\u003e\n    \u003cli\u003eMachine-level data processing and analysis.\u003c\/li\u003e\n    \u003cli\u003ePlatform for legacy automation software requiring Windows NT.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC BOX PC 840 V2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCeleron 2.0 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eFront Side Bus (FSB)\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e400 MHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProcessor Cache\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e128 KB SLC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e256 MB DDR SDRAM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e80 GB EIDE Hard Disk Drive\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOptical \/ Removable Media\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDVD-ROM Drive, Floppy Disk Drive (FDD)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGraphics\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOnboard AGP with 8\/16\/32 MB Shared Memory\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eEthernet Interface\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e1 x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eUSB Interface\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e2 x USB (High Current)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eExpansion Slots\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e2 x PCI, 2 x ISA\/PCI, 1 x ISA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e110\/230V AC Industrial Power Unit with NAMUR\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWindows NT 4.0 Workstation English, Service Pack 6a\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSystem Monitoring\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWatchdog, Temperature Monitoring\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e5.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e85381091\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin (Estimate)\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e55 cm x 45 cm x 25 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 16px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 24px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present within this equipment. All installation, maintenance, and removal procedures must be performed by qualified personnel only. Ensure the main power supply is de-energized and locked out\/tagged out (LOTO) before accessing any internal components or making connections.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eSite Preparation:\u003c\/strong\u003e Verify the installation environment meets the PC's operational requirements for temperature, humidity, and vibration. Ensure adequate clearance for ventilation around the chassis to prevent overheating.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Securely mount the Box PC chassis to a stable panel or surface using all designated mounting points. Use appropriate hardware and torque settings to prevent loosening due to machine vibration.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eProtective Earth (PE) Connection:\u003c\/strong\u003e Connect the chassis PE terminal to the facility's main protective earth bus using a low-impedance conductor. This is a critical step for electrical safety and noise immunity.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003ePower and I\/O Wiring:\u003c\/strong\u003e Connect the AC power supply cable to a properly rated and protected circuit. Connect all peripheral and network cables (Ethernet, USB, video). Ensure all cable shields are properly terminated as required.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003e\u003cstrong\u003eFinal Checks and Power-Up:\u003c\/strong\u003e Before applying power, double-check all connections for correctness and security. Remove all tools and foreign objects from the enclosure. Close and secure all access panels. Re-energize the main power supply and boot the system.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716572213611,"sku":"6ES7647-6MA12-0BC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-6ma12-0bc0-bn5jbn4hjpf_02882805-bb4b-46c4-aebf-57825ca43970.jpg?v=1767086006","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6es7647-6ma12-0bc0-simatic-box-pc-840-v2-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}