{"product_id":"siemens-6es7647-7ak30-1ab0-simatic-microbox-pc-427b-industrial-pc","title":"Siemens 6ES7647-7AK30-1AB0 SIMATIC MICROBOX PC 427B Industrial PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe Siemens 6ES7647-7AK30-1AB0 is a SIMATIC MICROBOX PC 427B, a compact and robust industrial computer designed for automation tasks. This specific configuration features a \u003cstrong\u003ePentium M 1.4 GHz\u003c\/strong\u003e processor, \u003cstrong\u003e1 GB of DDR2 RAM\u003c\/strong\u003e, and an \u003cstrong\u003e80 GB SATA hard disk drive\u003c\/strong\u003e for local data storage and application hosting. It comes pre-installed with Windows XP Professional (Multi-Language) and is equipped with an integrated \u003cstrong\u003ePROFIBUS DP 12\u003c\/strong\u003e interface and a second RS232 serial port for enhanced connectivity in industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eProcessor: Intel Pentium M operating at 1.4 GHz\u003c\/li\u003e\n\u003cli\u003eMemory: 1 GB DDR2 533 SODIMM\u003c\/li\u003e\n\u003cli\u003eStorage: 80 GB SATA Hard Disk Drive (HDD)\u003c\/li\u003e\n\u003cli\u003eOperating System: Windows XP Professional, Multi-Language Edition\u003c\/li\u003e\n\u003cli\u003eIndustrial Communication: Integrated PROFIBUS DP 12 interface\u003c\/li\u003e\n\u003cli\u003eSerial Connectivity: Includes a second RS232 interface in an extension frame\u003c\/li\u003e\n\u003cli\u003eCompact, fanless design suitable for control cabinet mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eHuman-Machine Interface (HMI) and SCADA visualization\u003c\/li\u003e\n\u003cli\u003eData logging, acquisition, and processing\u003c\/li\u003e\n\u003cli\u003eSmall-scale process control and automation gateways\u003c\/li\u003e\n\u003cli\u003eMachine vision and quality control systems\u003c\/li\u003e\n\u003cli\u003eIndustrial communication and protocol conversion\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC MICROBOX PC 427B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePentium M 1.4 GHz, 400 MHz FSB, 2 MB SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1 GB DDR2 533, SODIMM (1 x 1 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eStorage Drive\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e80 GB HDD SATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWindows XP Professional, Multi-Language\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIntegrated Interfaces\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFIBUS DP 12, Second RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2.60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e40.5 x 22.0 x 26.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 15px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 20px;\"\u003e\n\u003cp style=\"color: #c53030; font-weight: bold; margin: 0;\"\u003eCRITICAL WARNING: RISK OF ELECTRIC SHOCK\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-top: 5px; margin-bottom: 0;\"\u003eDisconnect all power sources before installation or maintenance. This equipment must be installed in a grounded, fire-proof enclosure by qualified personnel only. Failure to comply can result in severe injury or equipment damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 15px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Verify that the control cabinet and all related power sources are de-energized and locked out (LOTO) before beginning installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 15px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Mount the PC securely onto a standard DIN rail or a flat panel inside the control cabinet. Ensure adequate clearance for ventilation and cable access.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 15px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eProtective Earth (PE) Connection:\u003c\/strong\u003e Connect the chassis grounding terminal to the cabinet's main protective earth bus using a low-impedance conductor. This is critical for noise immunity and safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 15px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eConnect Power:\u003c\/strong\u003e Connect the specified DC power supply to the PC's power input terminals. Verify correct polarity before energizing the circuit.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 15px;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003e\u003cstrong\u003eInterface Cabling:\u003c\/strong\u003e Connect PROFIBUS, RS232, and any other required communication cables. Use shielded, twisted-pair cabling for all data lines and ensure shields are properly terminated at one end to the system ground.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716371476843,"sku":"6ES7647-7AK30-1AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-7ak30-1ab0-echeovukbga_7b747936-e58c-42ba-95fa-1327b1912d04.jpg?v=1767081505","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6es7647-7ak30-1ab0-simatic-microbox-pc-427b-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}