{"product_id":"siemens-6es7647-7bk40-0db0-simatic-ipc427c-microbox-pc","title":"Siemens 6ES7647-7BK40-0DB0 SIMATIC IPC427C Microbox PC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6ES7647-7BK40-0DB0\u003c\/strong\u003e is a SIMATIC \u003cstrong\u003eIPC427C\u003c\/strong\u003e Microbox PC designed for industrial automation applications. This compact industrial PC features a Core 2 Duo 1.2 GHz processor with an 800 MHz Front Side Bus (FSB) and 3 MB Second Level Cache (SLC). It is equipped with 4 GB of DDR3 1066 SODIMM memory and a 50 GB Solid-State-Drive (SATA) with high endurance, which is replaceable. The unit comes with Windows XP Professional Multi-Language pre-installed and includes a PROFIBUS DP 12 interface for communication within industrial control systems.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCore 2 Duo 1.2 GHz Processor with 800 MHz FSB and 3 MB SLC\u003c\/li\u003e\n\u003cli\u003e4 GB DDR3 1066 SODIMM Memory Configuration\u003c\/li\u003e\n\u003cli\u003e50 GB Solid-State-Drive (SATA, High Endurance)\u003c\/li\u003e\n\u003cli\u003ePROFIBUS DP 12 Communication Interface\u003c\/li\u003e\n\u003cli\u003ePre-installed Windows XP Professional Multi-Language Operating System\u003c\/li\u003e\n\u003cli\u003eReplaceable Mass Storage Drive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe SIMATIC IPC427C Microbox PC is suitable for various industrial applications requiring a robust and compact computing solution, including:\n\u003cul\u003e\n\u003cli\u003eMachine control and visualization\u003c\/li\u003e\n\u003cli\u003eData acquisition and processing\u003c\/li\u003e\n\u003cli\u003eDistributed control systems (DCS)\u003c\/li\u003e\n\u003cli\u003eHuman Machine Interface (HMI) tasks\u003c\/li\u003e\n\u003cli\u003eEmbedded control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Box PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eSubrange\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIPC427C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC Microbox\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCore 2 Duo 1.2 GHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eFront Side Bus (FSB)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e800 MHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eSecond Level Cache (SLC)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eMemory Configuration\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 GB DDR3 1066, SODIMM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eHardware Extension\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout expansions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eDrive Type\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSolid-State-Drive SATA (high endurance)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eDrive Capacity\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e50 GB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOperating System\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Prof. Multi-Language (pre-installed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS DP 12\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Phase\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e76.00 x 22.00 x 5.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3.20 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eExport Control Regulations (ECCN)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area and connected equipment is disconnected and locked out before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the Microbox PC in a suitable industrial enclosure or control cabinet, ensuring adequate ventilation and clearance for cable routing and heat dissipation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the appropriate power supply according to the system's electrical requirements. Verify correct polarity and grounding.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFIBUS Connection:\u003c\/strong\u003e Connect the PROFIBUS DP 12 cable to the designated port, ensuring proper termination and shielding for reliable communication.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePeripheral Connections:\u003c\/strong\u003e Connect any necessary peripherals such as display, keyboard, and mouse to the available ports.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the Microbox PC and its enclosure are properly grounded to minimize electrical noise and ensure safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route all cables to prevent strain, interference, and damage, separating power and signal cables where possible.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Operate the device within its specified temperature and humidity ranges to ensure optimal performance and longevity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Up:\u003c\/strong\u003e After all connections are secure and verified, restore power to the system and observe for proper boot-up and operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716453593451,"sku":"6ES7647-7BK40-0DB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-7bk40-0db0-frhobsnjkfc_46f00451-205c-4c82-ae61-5b061de8f5fd.jpg?v=1767083051","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6es7647-7bk40-0db0-simatic-ipc427c-microbox-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}