{"product_id":"siemens-6es7710-5da55-4fb4-simatic-field-pg","title":"Siemens 6ES7710-5DA55-4FB4 SIMATIC Field PG","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe 6ES7710-5DA55-4FB4 is a SIMATIC Field PG from Siemens, a ruggedized portable computer designed for industrial automation engineering tasks. This unit is equipped with a \u003cstrong\u003e1 GHz Pentium III\u003c\/strong\u003e processor, \u003cstrong\u003e512 MB of SDRAM\u003c\/strong\u003e, and a \u003cstrong\u003e40 GB EIDE hard drive\u003c\/strong\u003e. It comes pre-loaded with a suite of Siemens engineering software, including STEP 7 Professional, STEP 5, and STEP 7 Micro\/WIN, based on a December 2002 installation image. The integrated DVD-ROM\/CD-RW and 1.44 MB floppy disk drives provide flexible options for data transfer and software installation in legacy environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eProcessor: Intel Pentium III operating at 1 GHz\u003c\/li\u003e\n  \u003cli\u003eMemory: 512 MB SDRAM (configured as 2x256 MB modules)\u003c\/li\u003e\n  \u003cli\u003eStorage: 40 GB EIDE Hard Disk Drive (HDD)\u003c\/li\u003e\n  \u003cli\u003eOptical Drive: Combination DVD-ROM \/ CD-RW drive\u003c\/li\u003e\n  \u003cli\u003eLegacy Media: Integrated 1.44 MB floppy disk drive\u003c\/li\u003e\n  \u003cli\u003ePre-installed Software: STEP 7 Professional, STEP 5, STEP 7 Micro\/WIN\u003c\/li\u003e\n  \u003cli\u003eOperating System: Windows 2000 MUI (Multi-User Interface)\u003c\/li\u003e\n  \u003cli\u003eIncluded Accessories: Power cable for select European countries\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eCommissioning and startup of PLC and HMI systems\u003c\/li\u003e\n  \u003cli\u003eOn-site diagnostics and troubleshooting of industrial controllers\u003c\/li\u003e\n  \u003cli\u003eProgramming and software maintenance for SIMATIC S5 and S7 systems\u003c\/li\u003e\n  \u003cli\u003eData archiving and project management in field environments\u003c\/li\u003e\n  \u003cli\u003eInterfacing with legacy automation equipment requiring serial or parallel ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePentium III, 1 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eL2 Cache\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e256 KB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e512 MB (2 x 256 MB SDRAM)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eHard Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e40 GB EIDE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDVD-ROM \/ CD-RW Combination Drive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eFloppy Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1.44 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWindows 2000 MUI GEFSI\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003ePre-installed Software\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSTEP 7 Professional, STEP 5, STEP 7 Micro\/WIN (Inst. 12\/2002)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e4.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e29.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e84713000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; color: #2d3748; font-weight: bold;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e This is an obsolete electronic device. The hard drive and other components are subject to age-related failure. Immediately upon receipt, create a full backup or image of the hard drive to preserve the installed legacy software and system configuration. Handle with care to prevent data loss.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\n      \u003cstrong\u003eSite Preparation:\u003c\/strong\u003e Operate the Field PG on a stable, level, and vibration-free surface. Ensure adequate ventilation around the unit's chassis to prevent overheating. Avoid environments with excessive dust, moisture, or corrosive agents.\n    \u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\n      \u003cstrong\u003ePower Connection:\u003c\/strong\u003e Use only the provided power cable or a certified equivalent compatible with the local mains voltage. Connect the power cable securely to the Field PG's power inlet and to a properly grounded AC outlet.\n    \u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\n      \u003cstrong\u003eInitial Startup \u0026amp; Backup:\u003c\/strong\u003e Before connecting to any industrial network or PLC, power on the unit and allow the operating system to load fully. Verify the functionality of the pre-installed software. Perform a complete system backup as recommended in the warning above.\n    \u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\n      \u003cstrong\u003eInterface Connection:\u003c\/strong\u003e Connect communication cables (e.g., MPI, PROFIBUS, Ethernet) to the appropriate ports. Ensure connectors are fully seated and secured. When connecting to live industrial equipment, follow all site-specific safety and lockout\/tagout (LOTO) procedures.\n    \u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716588728683,"sku":"6ES7710-5DA55-4FB4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7710-5da55-4fb4-4xpv3ffozwz_ae9dc06c-ac35-4e11-b7a7-d4e1a12ac7e1.jpg?v=1767086280","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6es7710-5da55-4fb4-simatic-field-pg","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}