{"product_id":"siemens-6fx1112-1ae00-siemens-sirotec-master-slave-interface-module","title":"Siemens 6FX1112-1AE00 | Siemens | Module d’interface maître\/esclave SIROTEC  ","description":"\u003cp\u003eThe \u003cstrong\u003e6FX1112-1AE00\u003c\/strong\u003e is a specialized \u003cstrong\u003eSIROTEC Master\/Slave Interface Module\u003c\/strong\u003e from the \u003cstrong\u003eSINUMERIK\u003c\/strong\u003e product range, designed to facilitate high-speed data communication between automation components. This module utilizes a \u003cstrong\u003eV.24\u003c\/strong\u003e (also known as RS-232) physical interface standard and supports data transfer rates up to \u003cstrong\u003e8 MHz\u003c\/strong\u003e, making it a critical component for legacy CNC and motion control systems requiring synchronized signal exchange.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIROTEC Connectivity:\u003c\/strong\u003e Engineered for the SIROTEC ecosystem, ensuring seamless signal compatibility in legacy Siemens control environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Transmission:\u003c\/strong\u003e Supports communication frequencies up to 8 MHz for time-critical industrial data tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaster\/Slave Architecture:\u003c\/strong\u003e Facilitates organized data flow between primary controllers and secondary slave devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eV.24 Interface:\u003c\/strong\u003e Implements the V.24 standard, a foundational serial communication protocol for legacy CNC and industrial equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLegacy CNC machine tool signal coordination.\u003c\/li\u003e\n\u003cli\u003eMaintenance and repair of existing SINUMERIK-based automated control systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial networking where V.24\/RS-232 communication standards are mandated.\u003c\/li\u003e\n\u003cli\u003eSignal synchronization between specialized process controllers and master stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6FX1112-1AE00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eSINUMERIK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Standard\u003c\/td\u003e\n\u003ctd\u003eV.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Frequency\u003c\/td\u003e\n\u003ctd\u003e8 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e20.30 cm x 2.50 cm x 27.90 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is installed in a clean, dry environment within the control cabinet, adhering to the mounting pattern for SINUMERIK interface modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Use shielded cables for V.24 communication to prevent electromagnetic interference (EMI) from affecting high-frequency signals. Ensure that cable lengths do not exceed the distance limitations specified for the V.24 standard at 8 MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Verify that the Master\/Slave settings are correctly defined via the internal jumpers or software configuration settings as required by your specific system architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integrity:\u003c\/strong\u003e As this is an obsolete component, check that the connector pins are clean and free of oxidation before installation to ensure a reliable physical layer connection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716784779627,"sku":"6FX1112-1AE00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6fx1112-1ae00-ggwbprd2lqo_856d3706-d3f5-4165-95b5-075359cd127b.jpg?v=1767089690","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6fx1112-1ae00-siemens-sirotec-master-slave-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}