{"product_id":"siemens-6gk1561-3aa01-simatic-net-cp-5613-a2-communications-processor","title":"Siemens 6GK1561-3AA01 SIMATIC NET CP 5613 A2 Communications Processor","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK1561-3AA01 is a CP 5613 A2 communications processor designed for legacy industrial automation systems. This module is implemented as a \u003cstrong\u003ePCI card\u003c\/strong\u003e, providing a direct and reliable connection to \u003cstrong\u003ePROFIBUS\u003c\/strong\u003e networks. It features a DP-RAM interface specifically for \u003cstrong\u003eDP master\u003c\/strong\u003e operations and offers support for both \u003cstrong\u003ePG and FDL protocols\u003c\/strong\u003e. This unit is intended for established applications running on operating systems up to Windows XP. The package includes the necessary DP-Base software, configuration tools, and runtime software on a CD-ROM. For systems requiring support for operating systems newer than Windows XP, the successor model 6GK1561-3AA02 is recommended.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003ePCI card form factor for integration into industrial PCs.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eEnables PROFIBUS network connectivity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eFunctions as a PROFIBUS DP master.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSupports PG and FDL communication protocols.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eIncludes DP-Base software, configuration tool, and runtime software.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSingle license for one installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eLegacy manufacturing and production lines.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eProcess control systems requiring PROFIBUS DP master capabilities.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003ePC-based automation and control stations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eData acquisition and monitoring systems on older platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 300px;\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6GK1561-3AA01\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC NET\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommunications Processor (CP 5613 A2)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eForm Factor\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePCI Card\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eNetwork Connectivity\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePROFIBUS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSupported Protocols\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDP (Master), PG, FDL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eInterface\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDP-RAM\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSoftware Included\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDP-Base, Configuration Tool, Runtime Software\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSupported Operating Systems\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eUp to Windows XP (Legacy applications only)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePhase-Out\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e0.60 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e12.70 x 5.10 x 17.80 cm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85176200\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEAR99\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Calculated)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0; color: #c53030; font-weight: bold;\"\u003eCRITICAL WARNING: Electrical Hazard\u003c\/p\u003e\n    \u003cp style=\"margin: 8px 0 0 0; color: #2d3748;\"\u003eDisconnect all power from the host computer and follow all Lockout\/Tagout (LOTO) procedures before opening the chassis or handling the module. Failure to de-energize the system can result in severe electrical shock, equipment damage, and personal injury.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e1\u003c\/span\u003e\n        \u003c\/span\u003e\n        Ensure the host PC is fully de-energized and disconnected from its power source. Verify zero energy state.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e2\u003c\/span\u003e\n        \u003c\/span\u003e\n        Use a properly grounded electrostatic discharge (ESD) wrist strap and connect it to an unpainted metal surface of the computer chassis to prevent static damage to the card.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e3\u003c\/span\u003e\n        \u003c\/span\u003e\n        Open the computer chassis and select a vacant, compatible PCI slot. Remove the corresponding metal slot cover from the back of the chassis.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e4\u003c\/span\u003e\n        \u003c\/span\u003e\n        Carefully align the card's edge connector with the PCI slot and press down firmly and evenly until the card is fully seated.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e5\u003c\/span\u003e\n        \u003c\/span\u003e\n        Secure the card's metal mounting bracket to the chassis using the screw removed from the slot cover.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e6\u003c\/span\u003e\n        \u003c\/span\u003e\n        Connect the PROFIBUS network cable to the port on the card's bracket. Ensure the connector is securely fastened.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e7\u003c\/span\u003e\n        \u003c\/span\u003e\n        Replace the computer chassis cover, reconnect power, and proceed with software installation and configuration.\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716781928811,"sku":"6GK1561-3AA01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk1561-3aa01-nzoohvkjf4m_c72b2ad8-1085-446a-a7e3-ee4ba5d14830.jpg?v=1767089574","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6gk1561-3aa01-simatic-net-cp-5613-a2-communications-processor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}