{"product_id":"siemens-6gk5204-0ja00-2ba6-scalance-x204irt-pro-managed-ie-irt-switch","title":"Siemens 6GK5204-0JA00-2BA6 SCALANCE X204IRT PRO Commutateur IE IRT géré","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6GK5204-0JA00-2BA6\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE X204IRT PRO\u003c\/strong\u003e managed Industrial Ethernet (IE) IRT switch, designed for robust industrial networking applications. This device features a high degree of protection, \u003cstrong\u003eIP65\/67\u003c\/strong\u003e, making it suitable for deployment in harsh environments. It is equipped with four 10\/100 Mbit\/s Push-pull RJ45 ports for reliable data connections. The switch includes an error signaling contact with a set button and supports a redundant power supply for enhanced operational reliability. Functioning as a PROFINET IO device, it integrates network management capabilities and an embedded Redundancy Manager. An electronic manual on CD-ROM is included, and a C-plug is available as an optional accessory.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged Industrial Ethernet (IE) IRT Switch\u003c\/li\u003e\n\u003cli\u003eIP65\/67 Degree of Protection\u003c\/li\u003e\n\u003cli\u003e4x 10\/100 Mbit\/s Push-pull RJ45 Ports\u003c\/li\u003e\n\u003cli\u003eIntegrated Error Signaling Contact with Set Button\u003c\/li\u003e\n\u003cli\u003eRedundant Power Supply Capability\u003c\/li\u003e\n\u003cli\u003ePROFINET IO Device Functionality\u003c\/li\u003e\n\u003cli\u003eNetwork Management Support\u003c\/li\u003e\n\u003cli\u003eIntegrated Redundancy Manager\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe Siemens SCALANCE X204IRT PRO switch is suitable for a range of industrial applications requiring reliable and managed network communication in challenging environments. Typical deployments include:\n\u003cul\u003e\n\u003cli\u003eDistributed PROFINET IO systems in machine building and plant engineering.\u003c\/li\u003e\n\u003cli\u003eIndustrial automation networks requiring high availability and real-time communication.\u003c\/li\u003e\n\u003cli\u003eApplications in harsh industrial environments where IP65\/67 protection is necessary.\u003c\/li\u003e\n\u003cli\u003eIntegration into network architectures requiring redundancy management for enhanced uptime.\u003c\/li\u003e\n\u003cli\u003eConnecting field devices and controllers in production lines and manufacturing facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK5204-0JA00-2BA6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManaged IE IRT Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDegree of Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIP65\/67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePorts\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x 10\/100 Mbit\/s Push-pull RJ45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRedundant\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET IO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Management\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupported\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRedundancy Manager\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegrated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e9.00 x 12.40 x 12.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.90 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUnknown\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized and locked out before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The IP65\/67 rating allows for direct machine mounting in harsh environments. Secure the device firmly using appropriate fasteners to prevent vibration or accidental dislodgement.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the redundant power supply leads to the designated terminals. Observe correct polarity. Ensure the power sources are stable and within the specified voltage range for industrial equipment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNetwork Cabling:\u003c\/strong\u003e Utilize industrial-grade Ethernet cables with Push-pull RJ45 connectors for the 10\/100 Mbit\/s ports. Ensure cables are securely latched and routed to avoid strain, sharp bends, or interference from power lines.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eError Signaling Contact:\u003c\/strong\u003e Connect the error signaling contact to a monitoring system or PLC input as required for system diagnostics and alerts. Test the signaling function after installation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the device is properly grounded according to local electrical codes and industrial best practices to protect against electrical noise and surges.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Refer to the electronic manual on the included CD-ROM for initial setup, network configuration, and integration into the PROFINET IO system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716767773035,"sku":"6GK5204-0JA00-2BA6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5204-0ja00-2ba6-qm2utikm2zq_c4783804-c957-44b0-a00e-05921ceef89f.jpg?v=1767089065","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6gk5204-0ja00-2ba6-scalance-x204irt-pro-managed-ie-irt-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}