{"product_id":"siemens-6gk5224-0ba00-2aa3-scalance-x224-managed-industrial-ethernet-switch","title":"Commutateur Ethernet industriel géré SCALANCE X224 Siemens 6GK5224-0BA00-2AA3","description":"\u003cp\u003eThe \u003cstrong\u003e6GK5224-0BA00-2AA3\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE X224\u003c\/strong\u003e managed industrial Ethernet switch, designed to provide high-density connectivity and robust network management for complex automation systems. Featuring 24 x 10\/100 Mbit\/s RJ45 ports, this switch is optimized for reliable data exchange in production environments. It supports advanced features such as PROFINET IO device compatibility, redundant power supply capabilities, and the ability to operate within redundant ring topologies for maximum network availability. Maintenance is streamlined through integrated LED diagnostics and an error-signaling contact with an accessible set button, while the optional C-PLUG allows for simplified configuration storage and device swapping.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Port Density:\u003c\/strong\u003e 24 x 10\/100 Mbit\/s RJ45 ports for extensive device integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Supports operation in redundant ring topologies to prevent network downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Integrated LED status indicators and error-signaling contact for proactive maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Management:\u003c\/strong\u003e PROFINET IO device compliant with full network management capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Power:\u003c\/strong\u003e Redundant power supply input to ensure continuous operation during power faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance:\u003c\/strong\u003e Optional C-PLUG support for quick configuration backup and deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge-scale production floor networking.\u003c\/li\u003e\n\u003cli\u003ePROFINET-based automation and drive control systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial environments requiring redundant network topologies.\u003c\/li\u003e\n\u003cli\u003eInfrastructure where real-time diagnostics and high port counts are critical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSIMATIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e24 x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Features\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO, Redundancy Manager, VLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.80 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18.00 cm x 12.40 cm x 12.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003e5A002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for standard DIN rail mounting or wall mounting. Ensure the installation area allows for adequate heat dissipation around the chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Configuration:\u003c\/strong\u003e When setting up a redundant ring, ensure all switches in the ring are configured to support the redundancy manager protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Connect redundant power sources to the dedicated terminals to enable the switch's failover protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Test the error-signaling contact during commissioning to ensure that control room alarms trigger correctly if a fault is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-PLUG:\u003c\/strong\u003e Insert the optional C-PLUG before commissioning to ensure network configuration is automatically backed up to the external memory.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716779897195,"sku":"6GK5224-0BA00-2AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5224-0ba00-2aa3-nwoi3sjrxky_a2701966-6324-4d91-b9f5-cf0387344bc6.jpg?v=1767089496","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6gk5224-0ba00-2aa3-scalance-x224-managed-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}