{"product_id":"siemens-6gk5308-2gg10-2aa2-scalance-x308-2m-managed-industrial-ethernet-switch","title":"Siemens 6GK5308-2GG10-2AA2 SCALANCE X308-2M Commutateur Ethernet industriel géré","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5308-2GG10-2AA2 is a SCALANCE X308-2M compact managed Industrial Ethernet switch designed for machine-level networking and control cabinet installation. It provides a flexible port configuration with \u003cstrong\u003efour fixed 10\/100\/1000 Mbit\/s RJ45 ports\u003c\/strong\u003e and \u003cstrong\u003etwo slots for 2-port media modules\u003c\/strong\u003e, allowing for either electrical or optical connections at 100\/1000 Mbit\/s. As a PROFINET IO device with an integrated redundancy manager, this switch ensures high network availability and seamless integration into Siemens automation environments. The unit includes a C-PLUG in the scope of delivery for simple configuration backup and device replacement.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eManaged Layer 2 switching capabilities for network control.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eIntegrated redundancy manager to enhance network uptime.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eFunctions as a PROFINET IO device for diagnostics and system integration.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eSupports standard office IT protocols including RSTP, VLAN, and IGMP.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eEquipped with LED diagnostics, an error signaling contact, and a select\/set button for on-site management.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eIncludes a C-PLUG removable memory module for configuration storage.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eFactory and plant automation networks requiring high availability.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eMachine-level data aggregation and communication.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eIntegration of PROFINET-enabled devices into a structured Ethernet network.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eControl systems requiring network segmentation via VLANs.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 400px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px 8px; background-color: #f7fafc; font-weight: 600;\"\u003eProduct Identification\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eSCALANCE X-300\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eSCALANCE X308-2M\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e6GK5308-2GG10-2AA2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px 8px; background-color: #f7fafc; font-weight: 600;\"\u003eInterfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eElectrical Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e4 x RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eElectrical Port Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e10\/100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eMedia Module Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e2 (for 2-port media modules, electrical or optical)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eMedia Module Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px 8px; background-color: #f7fafc; font-weight: 600;\"\u003eFunctionality\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eSupported Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003ePROFINET IO, RSTP, VLAN, IGMP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eC-PLUG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px 8px; background-color: #f7fafc; font-weight: 600;\"\u003eLogistics and Compliance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e0.90 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e12.0 cm x 12.4 cm x 12.5 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e85389091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px 16px; background-color: #fff5f5; border-left: 4px solid #c53030; margin: 16px 0;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. Disconnect and lock out all power sources before installation or maintenance to prevent electric shock or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eDe-energize Panel:\u003c\/strong\u003e Verify the control cabinet is completely de-energized and follow all applicable Lockout\/Tagout (LOTO) procedures before beginning work.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount Switch:\u003c\/strong\u003e Securely mount the SCALANCE switch onto a standard 35mm DIN rail within the enclosure, ensuring adequate clearance for ventilation and cable access.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Functional Ground:\u003c\/strong\u003e Connect the functional earth (FE) terminal on the switch to the cabinet's equipotential bonding rail using a low-impedance conductor.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect the specified DC power source to the power supply terminal block, observing correct polarity. If redundant power supplies are used, connect both.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Network Cables:\u003c\/strong\u003e Connect shielded Ethernet cables to the RJ45 ports. If using media modules, install them into the slots and connect the corresponding cables. Ensure proper cable routing and strain relief.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower On and Verify:\u003c\/strong\u003e After ensuring all connections are secure, re-energize the cabinet. Observe the device LEDs to confirm power status, network link, and activity.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716664947051,"sku":"6GK5308-2GG10-2AA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5308-2gg10-2aa2-ulotuq2hmpx_57bd92f6-369e-4405-bdb0-927fbeadaf85.jpg?v=1767087587","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-6gk5308-2gg10-2aa2-scalance-x308-2m-managed-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}