{"product_id":"siemens-simatic-panel-pc-670-6av7611-0aa20-0cj0-panel-pc","title":"Siemens SIMATIC Panel PC 670 6AV7611-0AA20-0CJ0 Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7611-0AA20-0CJ0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This unit features a \u003cstrong\u003e10-inch TFT display\u003c\/strong\u003e and is equipped with an \u003cstrong\u003eIntel Celeron 300 MHz processor\u003c\/strong\u003e, \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e. It is configured to operate on a \u003cstrong\u003e115-230V AC\u003c\/strong\u003e power supply and comes pre-installed with the Windows NT 4.0 English operating system. This model is a legacy component, noted as an obsolete product in the product lifecycle management phase, suitable for maintaining existing systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated 10-inch TFT color display\u003c\/li\u003e\n  \u003cli\u003ePowered by an Intel Celeron 300 MHz CPU\u003c\/li\u003e\n  \u003cli\u003eIncludes 128 MB of system RAM\u003c\/li\u003e\n  \u003cli\u003eEquipped with a 20 GB internal hard drive\u003c\/li\u003e\n  \u003cli\u003ePre-loaded with Microsoft Windows NT 4.0 (English version)\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range of 115-230V AC\u003c\/li\u003e\n  \u003cli\u003eSupplied with a European mains power cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProcess visualization and control\u003c\/li\u003e\n  \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes\u003c\/li\u003e\n  \u003cli\u003eMachine-level data logging and diagnostics\u003c\/li\u003e\n  \u003cli\u003eFactory automation and assembly line monitoring\u003c\/li\u003e\n  \u003cli\u003eReplacement unit for existing SIMATIC PC 670 installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 10px 12px; border: 1px solid #e2e8f0; background-color: #f7fafc; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 10px 12px; border: 1px solid #e2e8f0; background-color: #f7fafc; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e6AV7611-0AA20-0CJ0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePanel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e10-inch TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProcessor (CPU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eIntel Celeron 300 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e128 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e20 GB Hard Drive (HD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWindows NT 4.0 (English)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e115-230 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eEuropean Mains Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e4.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e40 cm x 30 cm x 15 cm (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: Electrical Hazard\u003c\/p\u003e\n  \u003cp style=\"color: #2d3748; margin-bottom: 0;\"\u003eInstallation must be performed by qualified personnel only. Disconnect and lock out all power sources to the enclosure before installing or servicing this equipment. Failure to de-energize the system can result in severe injury or death.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eVerify that the panel cutout dimensions match the PC 670 specifications for a secure fit. Ensure the mounting surface is clean, flat, and can support the unit's weight.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eInsert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's recommended torque to ensure a proper seal.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eConnect a dedicated protective earth (PE) conductor to the designated grounding terminal on the chassis. A low-impedance ground connection is essential for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eConnect the 115-230V AC power supply using the provided mains cable. Ensure the source voltage is stable and within the specified range. Route power cables separately from signal and communication lines.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eConnect all required peripheral and communication cables (e.g., Ethernet, serial, USB) to their respective ports. Ensure all connectors are fully seated and secured.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003eAfter all connections are verified, remove the lockout\/tagout device and re-energize the main power supply to the enclosure. Power on the Panel PC and confirm proper boot-up and operation.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716406636907,"sku":"6AV7611-0AA20-0CJ0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7611-0aa20-0cj0-f1gl2cbuspq_7b21969b-7e37-4527-a30f-f3418037c788.jpg?v=1767082283","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-simatic-panel-pc-670-6av7611-0aa20-0cj0-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}