{"product_id":"siemens-simatic-panel-pc-670-6av7613-0ab22-0cf0-panel-pc","title":"Siemens SIMATIC Panel PC 670 6AV7613-0AB22-0CF0 Panel PC","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens SIMATIC Panel PC 670, model \u003cstrong\u003e6AV7613-0AB22-0CF0\u003c\/strong\u003e, an industrial-grade human-machine interface (HMI) designed for machine-level control and visualization tasks. It features a \u003cstrong\u003e12-inch TFT display\u003c\/strong\u003e integrated into a rugged enclosure suitable for demanding plant-floor environments. Please note that this product line is designated as obsolete by the manufacturer, making it a critical spare part for maintaining existing automation systems.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eIntegrated 12-inch TFT color display\u003c\/li\u003e\n\u003cli\u003ePart of the SIMATIC Panel PC 670 series\u003c\/li\u003e\n\u003cli\u003eDesigned for industrial panel mounting\u003c\/li\u003e\n\u003cli\u003eObsolete product status, ideal for legacy system support\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eProcess visualization and control\u003c\/li\u003e\n\u003cli\u003eMachine data acquisition and monitoring\u003c\/li\u003e\n\u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes\u003c\/li\u003e\n\u003cli\u003eFactory automation HMI stations\u003c\/li\u003e\n\u003cli\u003eReplacement unit for existing PC 670 installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e12-inch TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e12.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eN (No License Required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e35.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 16px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect and lock out all power sources before installation or servicing. Work must be performed by qualified personnel only. Failure to de-energize equipment can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePrepare Panel Cutout:\u003c\/strong\u003e Ensure the mounting cutout in the enclosure or panel is clean, deburred, and matches the required dimensions for the PC 670 chassis. Verify adequate clearance for ventilation and cable routing at the rear of the unit.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front. Secure it evenly using all provided mounting clamps. Tighten the clamp screws in a cross-pattern to ensure a uniform seal against the panel gasket. Do not overtighten.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect the chassis grounding terminal to the cabinet's protective earth (PE) bus bar using a low-impedance conductor. A reliable ground connection is essential for safety and noise immunity.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Power and I\/O:\u003c\/strong\u003e Connect the main power supply to the designated terminals, verifying voltage and polarity. Connect all communication and I\/O cables, ensuring proper strain relief to prevent stress on the connectors.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePower-Up and Verification:\u003c\/strong\u003e After ensuring the work area is clear and all connections are secure, re-energize the main power supply. Verify that the Panel PC boots correctly and establishes communication with other system devices.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715820482923,"sku":"6AV7613-0AB22-0CF0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7613-0ab22-0cf0-dprl22wcnr0_5f8a422e-dd73-43fb-bdcc-24278d7eb9f4.jpg?v=1767071700","url":"https:\/\/www.plcprotech.com\/fr\/products\/siemens-simatic-panel-pc-670-6av7613-0ab22-0cf0-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}