{"product_id":"triconex-3604e-digital-output-module-24-vdc-16-point-tmr","title":"Module de sortie numérique 24 VDC 16 points TMR Triconex 3604E","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3604E (3604 E)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 24 VDC TMR Digital Output Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for safety critical shutdown and interlock systems. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3604E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides 16 non commoned output channels with full Triple Modular Redundant architecture. Each point uses independent drivers and hardware voting to ensure deterministic output control even during single channel failure.\u003c\/p\u003e\n\u003cp\u003eThe module is typically deployed in emergency shutdown systems, burner management systems, turbine protection, and compressor control panels. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3604E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates output voter diagnostics, loopback monitoring, and per point status indicators. These functions detect wiring faults, load failures, and driver degradation without interrupting operation. The module supports high current loads such as solenoids, relays, and trip valves while maintaining low leakage and high isolation.\u003c\/p\u003e\n\u003ch3\u003eOutput Circuit Design and Voting Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3604E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eimplements triplicated output circuitry with hardware voter logic:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThree independent output drivers per point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 out of 3 voting before field output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon commoned output architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReverse EMF protection on module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoopback diagnostic monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput voter diagnostics coverage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach output point contains dedicated status indicators including On Off state and fault monitoring. Diagnostic toggling verifies driver integrity and detects latent failures. Maximum toggle rate supports full diagnostic coverage during operation.\u003c\/p\u003e\n\u003cp\u003eThe module requires external fused field termination. Each output must be powered including unused points on non commoned panels to maintain diagnostic coverage.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications \u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3604E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTMR Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e16 non commoned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e22 to 45 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2.0 A per point maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e10 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Power\u003c\/td\u003e\n\u003ctd\u003eLess than 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 4 V typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eReverse diode on I O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Requirement\u003c\/td\u003e\n\u003ctd\u003e2.5 A fast acting per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Coverage\u003c\/td\u003e\n\u003ctd\u003eOutput voter diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003ePass Fault Active per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Indicators\u003c\/td\u003e\n\u003ctd\u003eOn Off per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e310 x 225 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg module only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e5 kg typical packed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Code\u003c\/td\u003e\n\u003ctd\u003eDark blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTricon chassis slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eSupported in TMR system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOutput Voltage Drop Characteristics\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCondition\u003c\/th\u003e\n\u003cth class=\"\"\u003eVoltage Drop\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane only\u003c\/td\u003e\n\u003ctd\u003eLess than 3 VDC typical at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane max load\u003c\/td\u003e\n\u003ctd\u003eLess than 3 VDC max at 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith 10 ft cable\u003c\/td\u003e\n\u003ctd\u003eLess than 4 VDC typical at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith 10 ft cable\u003c\/td\u003e\n\u003ctd\u003eLess than 5 VDC max at 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith 99 ft cable\u003c\/td\u003e\n\u003ctd\u003eLess than 6 VDC typical at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith 99 ft cable\u003c\/td\u003e\n\u003ctd\u003eLess than 11 VDC max at 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs 3604E a fully redundant output module?\u003c\/strong\u003e\u003cbr\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3604E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses triple driver paths with 2 out of 3 voting logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre outputs isolated from each other?\u003c\/strong\u003e\u003cbr\u003eYes. All 16 outputs are non commoned and individually isolated to 1500 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 3604E support inductive loads?\u003c\/strong\u003e\u003cbr\u003eYes. Built in reverse diode protection supports solenoids and relay coils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy must unused outputs be powered?\u003c\/strong\u003e\u003cbr\u003eDiagnostics require power on all points to detect wiring and driver faults.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eUse 2.5 A fast acting fuse per output on field termination panel. This protects driver circuits.\u003c\/p\u003e\n\u003cp\u003ePower must be applied to all output points including unused channels. This ensures full diagnostic coverage.\u003c\/p\u003e\n\u003cp\u003eInstall suppression devices on long cable runs. This reduces voltage drop and improves switching stability.\u003c\/p\u003e\n\u003ch3\u003eReliability and Safety Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3604E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides deterministic output control for SIL safety loops. Triplicated architecture eliminates single driver failures.\u003c\/p\u003e\n\u003cp\u003ePer point diagnostics detect open circuit, fuse failure, and load loss conditions. This reduces unsafe operation.\u003c\/p\u003e\n\u003cp\u003eHigh isolation and non commoned outputs prevent cross channel fault propagation. This improves system integrity.\u003c\/p\u003e\n\u003cp\u003eReverse EMF protection and surge capability support heavy inductive loads common in shutdown systems.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":53102421475691,"sku":"3604E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3604E-2dtsof5ngip.png?v=1776137104","url":"https:\/\/www.plcprotech.com\/fr\/products\/triconex-3604e-digital-output-module-24-vdc-16-point-tmr","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}