{"product_id":"triconex-8310-power-module-120-vac-vdc-175w","title":"Module d'alimentation Triconex 8310 | 120 VAC\/VDC 175W","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310 (8310)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, 175-Watt Power Module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriple Modular Redundant (TMR) safety system. Designed for high-availability environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides regulated DC power to the internal backplane, supporting the Main Processors, Communication Modules, and I\/O assemblies. This module is compatible with Main, Expansion, and Remote Expansion (RXM) chassis types. In critical industries such as oil and gas, chemical processing, and power generation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplays a vital role in preventing system-wide power failures. By supporting dual-redundant power configurations within a single chassis, it ensures that even the total loss of one power source does not compromise the Safety Instrumented System (SIS) or result in costly process downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Module is built to handle versatile input requirements while maintaining strict output regulation for the sensitive TMR electronics.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Source Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module is rated for both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120 VAC and 120 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enominal inputs, allowing it to interface with standard utility grids or industrial battery backup systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Input Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt remains operational through significant voltage fluctuations, accepting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e85–140 VAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(at 47-63 Hz) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e95–180 VDC\u003c\/strong\u003e, ensuring stable system performance during brownouts or surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach module is equipped with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 amp time-delay fuse\u003c\/strong\u003e, protecting the internal chassis backplane from over-current conditions and preventing fault propagation between modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhether installed in the Main Chassis or a Remote Expansion (RXM) rack, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a consistent 175-watt power envelope, sufficient to drive a fully populated rack of high-density I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTriconex\u003c\/strong\u003e (Schneider Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 VAC\/VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e175 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput VAC Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 to 140 VAC (47-63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput VDC Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 to 180 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Amps, Time-Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMain, Expansion, RXM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 8310 support redundant operation within the same chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. For full redundancy, a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echassis should be populated with two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules. Each module is capable of supporting the entire chassis load; if one fails or loses its input source, the other takes over the full load instantaneously without a system reset.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 8310 handle both AC and DC inputs simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module is rated for both, it typically receives one type of input per module. In a redundant configuration, it is common engineering practice to feed one\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom an AC UPS and the second\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom a 120 VDC station battery for maximum reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I identify a power module failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe front panel features a \"Pass\" and \"Fault\" LED. A \"Fault\" LED or the activation of the chassis alarm relay typically indicates a blown internal fuse or a failure in the internal voltage regulation circuitry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power Separation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor maximum safety integrity, route the power cables for the primary and redundant\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules through separate conduits. This prevents a single physical cable fire or accidental disconnect from disabling both power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Replacement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnly use official 5-amp time-delay fuses. Using a fast-acting fuse may result in nuisance blows during the initial inrush current when the chassis is first energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven its 175-watt rating, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egenerates significant heat during full-load operation. Ensure the chassis fan assembly is functional and that there is at least 15 cm of clearance above the cabinet to allow for heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Surge Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to withstand the electrical noise and spikes common in heavy industrial power grids, protecting the logic modules from damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module can be replaced while the system is online. By keeping one power module active, the failed unit can be swapped without stopping the process or losing any diagnostic data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeeting the stringent requirements for SIL 3 safety systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a globally recognized standard for power reliability in hazardous and mission-critical applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":53102421639531,"sku":"8310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8310-kxyvwrwykda.png?v=1776137147","url":"https:\/\/www.plcprotech.com\/fr\/products\/triconex-8310-power-module-120-vac-vdc-175w","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}