{"product_id":"vibro-meter-ipc704p-cp237-244-704-000-032-amp-module","title":"Module AMP Vibro-Meter IPC704P-CP237 244-704-000-032","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIPC704P-CP237 244-704-000-032\u003c\/strong\u003e is a configurable signal conditioner and charge amplifier module designed for critical industrial vibration measurement chains. This high-reliability \u003cstrong\u003eAMP MODULE\u003c\/strong\u003e processes alternative electrical charge signals generated by piezoelectric sensors, such as accelerometers or dynamic pressure transducers, and transforms them into standard industrial monitoring signals. The board features an optional integrator to directly produce a \u003cstrong\u003evelocity output\u003c\/strong\u003e from acceleration raw inputs, as well as highly flexible output electronics configured for either \u003cstrong\u003e2-wire current transmission\u003c\/strong\u003e or \u003cstrong\u003e3-wire voltage transmission\u003c\/strong\u003e. Engineered to maintain high signal linearity over long distances, it bridges the gap between field-mounted harsh environment sensors and centralized distributed control systems (DCS) or machinery protection racks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Filtering Network:\u003c\/strong\u003e Integrated high-pass and low-pass filtering allows narrow-band or broad-band path selection to match specific rotating machinery profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Board Integrator Option:\u003c\/strong\u003e Includes selectable hardware integration circuitry to flawlessly convert dynamic acceleration charge signals into a calibrated velocity value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Output Modes:\u003c\/strong\u003e Supports versatile interface options with configurable 2-wire constant-current loops or standard 3-wire voltage signal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Thermal Stability:\u003c\/strong\u003e Delivers dependable measurement continuity across broad environmental ranges, featuring low drift performance over temperature variations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Readiness:\u003c\/strong\u003e Certified for deployment in connection with potentially explosive atmospheres, providing robust protection in volatile process sectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and Steam Turbines:\u003c\/strong\u003e Condition monitoring and thermal tracking of high-frequency casing or structural vibration components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Processing Compressors:\u003c\/strong\u003e Direct signal amplification for dynamic fluid pressure pulsation sensors and centrifugal compressor monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePetrochemical Pumping Stations:\u003c\/strong\u003e Converting charge inputs from remote accelerometers mounted directly to high-speed heavy-duty pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerospace Propulsion Rigs:\u003c\/strong\u003e High-precision test cell analytics for dynamic vibration diagnostics under aggressive mechanical loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVibro-Meter (Parker Meggitt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIPC704P-CP237 244-704-000-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAMP MODULE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (Without Integrator)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 to 10 mV\/pC or 0.1 to 10 uA\/pC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (With Integrator)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e981 to 98 100 mV\/(pC.s) or 981 to 98 100 uA\/(pC.s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Configurable Transfer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 to 50 mV\/pC or 0.1 to 50 uA\/pC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Linearity Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Stability Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ppm \/ Celsius typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEstimated Shipping Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.7 x 18.5 x 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Input Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-noise high-impedance charge input for piezoelectric transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Output Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable terminal pins for 2-wire current or 3-wire voltage loop distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Selection:\u003c\/strong\u003e Install inside an appropriate housing or enclosure matching the selected site mounting options to shield the amplifier cards from environmental dust and humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Cable Shielding:\u003c\/strong\u003e Use premium low-noise coaxial cables for the sensor input to mitigate external EMI\/RFI interference on the high-impedance charge signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Sourcing:\u003c\/strong\u003e Energize the module utilizing a well-regulated 24 VDC power supply bounded within the explicit 18 to 30 VDC working limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity Check:\u003c\/strong\u003e Confirm all output wiring configurations before applying loop power to prevent hardware faults across the transmission line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Isolation:\u003c\/strong\u003e For explosive atmospheres, the module must be wired in series with certified safety barriers or isolation units to enforce intrinsic safety parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosive Atmospheres Approval:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres and designated industrial hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core function of the IPC704P-CP237 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module acts as a specialized charge amplifier that converts weak electrostatic charge signals from piezoelectric sensors into robust analog signals suitable for monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this amplifier card support direct velocity output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it contains an optional hardware integrator path that can be selected to automatically convert raw acceleration inputs into a standard velocity format.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the power requirements for this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit operates on an incoming DC voltage source ranging from 18 VDC to 30 VDC, drawing a maximum of 25 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be configured for both current and voltage outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device features flexible output stages that support both 2-wire constant-current transmission and 3-wire voltage transmission configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat types of sensors are typically compatible with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt works with standard high-impedance piezoelectric components, including CA series accelerometers and CP series dynamic pressure sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the standard signal frequency range for this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe amplifier covers an operational frequency spectrum spanning from 0.5 Hz up to 20 kHz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does temperature affect the calibration of this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe thermal drift is highly controlled, exhibiting a typical temperature stability rating of 100 ppm per Celsius.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to place this amplifier directly into hazardous areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is explicitly certified for explosive environments, provided it is deployed in strict compliance with original factory installation instructions and safe power limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the specified linearity error limit for the signal chain?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module ensures highly accurate tracking with a low linearity error of 0.2% or less across the operational spectrum.\u003c\/p\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":53240093802859,"sku":"IPC704P-CP237 244-704-000-032","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/200-510-SSS-1HH_1.png?v=1779888205","url":"https:\/\/www.plcprotech.com\/fr\/products\/vibro-meter-ipc704p-cp237-244-704-000-032-amp-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}