{"product_id":"vibro-meter-iqs-450-204-450-000-002-signal-conditioner","title":"Conditionneur de signal VIBRO-METER IQS 450 204-450-000-002","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS 450 204-450-000-002 (IQS450)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision signal conditioner that forms the essential bridge in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeddy-current measurement chain. It is engineered to work in tandem with TQ-series proximity transducers (such as the TQ 402 or TQ 412) to provide accurate, non-contact displacement and vibration monitoring for critical rotating machinery. By converting the complex impedance changes from the sensor into a standardized voltage or current signal, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS 450 204-450-000-002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables real-time monitoring of shaft position and vibration in steam turbines, compressors, and pumps, ensuring maximum machine availability and safety.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e204-450-000-002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration is a specific iteration of the IQS 450 platform, optimized for high-performance industrial applications.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEddy Current Principle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit drives the transducer's sensing coil with a high-frequency carrier signal. As the distance between the probe tip and the target changes, the IQS 450 detects the modulation and demodulates it into a precise analog output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Output Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis specific model is designed to support both voltage and current outputs, allowing it to interface seamlessly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack cards or direct-to-PLC inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Temperature Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe circuitry includes advanced compensation algorithms to neutralize the effects of ambient temperature fluctuations on the signal, ensuring that \"thermal drift\" does not result in false vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Housing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe electronics are encapsulated in a robust aluminum housing designed for DIN-rail mounting in junction boxes or local control panels near the machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIQS 450 204-450-000-002\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSwitzerland\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrom TQ 402 \/ TQ 412 Transducers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC to 20 kHz (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-18 to -30 VDC (Standard -24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-2 to -18 VDC \/ 4 to 20 mA (Config dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"002\" suffix indicate in this part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix typically denotes the hardware revision and factory calibration settings for the system length (e.g., a 5 m or 10 m total system length). It ensures the unit is matched to the electrical length of the transducer and extension cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify if the IQS 450 is functioning correctly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the quiescent output voltage (Gap Voltage) with the transducer connected. For a standard gapped sensor, you should see a stable DC voltage (typically around\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10 VDC\u003c\/strong\u003e). If the output is stuck at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor the supply rail limit, it indicates a short or open circuit in the transducer chain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with extension cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS 450 204-450-000-002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to be used with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEA 402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eextension cables. However, the total electrical length (Transducer + Extension) must match the calibration of the IQS 450 to maintain linearity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal System Length (TSL) Matching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is critical that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS 450\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis matched to the physical cable length of the sensor. Using a 5 m calibrated IQS 450 with a 10 m cable system will result in a 50% sensitivity error, leading to incorrect vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe miniature coaxial connectors (BNC or specialized) must be clean and dry. Use a torque wrench where specified, or hand-tighten until the self-locking mechanism engages. Moisture in these connectors is the #1 cause of \"intermittent signal noise\" in proximity systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IQS 450 housing should be electrically bonded to the DIN rail, which in turn must be connected to a clean instrument ground. This prevents electromagnetic interference (EMI) from variable frequency drives (VFDs) from polluting the high-frequency eddy current signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS 450 204-450-000-002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out due to its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExcellent Linearity and Low Noise Floor\u003c\/strong\u003e. In high-speed turbine applications, even a few micrometers of measurement error can be the difference between a normal run and an emergency trip. The IQS 450's refined demodulation circuitry provides a clean signal that allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem to perform high-resolution orbit analysis and Bode plots with laboratory-grade precision in the middle of a power plant floor.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695209247083,"sku":"IQS450 204-450-000-002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-iqs450-204-450-000-002-signal-conditioner-zh0zgdhbkiq_097b0071-8935-4961-816f-2bb43b741461.jpg?v=1766130781","url":"https:\/\/www.plcprotech.com\/fr\/products\/vibro-meter-iqs-450-204-450-000-002-signal-conditioner","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}