{"product_id":"vibro-meter-iqs450-204-450-000-001-signal-conditioner","title":"Conditionneur de signal Vibro-Meter IQS 450 (204-450-000-001)","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS 450 (204-450-000-001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance signal conditioner from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproduct line, specifically engineered for non-contacting proximity measurement systems. It serves as the critical link in an eddy current measurement chain, typically paired with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTQ 402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTQ 412\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransducer and an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEA 402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eextension cable. This unit converts the transducer's impedance changes into a standardized voltage or current signal proportional to the distance between the probe tip and the target shaft. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e204-450-000-001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration is widely used in power plants and petrochemical facilities for measuring shaft vibration and axial position in steam and gas turbines.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e204-450-000-001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant is a specific hardware build that ensures the high reliability required for industrial protective systems.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEddy Current Principle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit drives the transducer sensing coil with a high-frequency carrier signal and demodulates the resulting signal to provide a linear output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures sophisticated internal circuitry that compensates for thermal variations at the sensor end, maintaining measurement accuracy from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$-40^{\\circ}C$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$+180^{\\circ}C$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eat the transducer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports both voltage and current transmission. The current modulation allows for signal integrity over long distances (up to 1 km when used with a GSI unit).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterchangeability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePart of a calibrated system where the IQS 450, transducer, and extension cable are modular and interchangeable without requiring site-specific recalibration, provided the system lengths match.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ PNR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIQS 450 \/ 204-450-000-001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrom TQ 402, TQ 412, TQ 422, or TQ 432\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC to 20 kHz (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm or 4 mm (Probe dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-18 VDC to -30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-2 to -18 V (Voltage) \/ 15.5 to 20 mA (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to \u003cspan class=\"math-inline\"\u003e$+85^{\\circ}C$\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMoulded Aluminium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"001\" suffix in the part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e204-450-000-001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epart number typically identifies the specific revision or calibration grouping of the hardware. In the IQS 450 series, these suffixes often distinguish between standard and specialized mounting or output configurations. Always verify your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSL (Total System Length)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirement (e.g., 1m, 5m, or 10m) to ensure compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the IQS 450 with a different brand of proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Proximity systems rely on a specific carrier frequency and impedance matching between the transducer and the conditioner. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS 450\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed exclusively for the Vibro-Meter TQ-series transducers. Using a non-Vibro-Meter probe will result in a \"Sensor OK\" error and non-linear data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I check the health of the IQS 450 loop?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGap Voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat the output. A value near -10 VDC typically indicates the sensor is at the midpoint of its linear range. If the voltage is 0V or identical to the supply rail (e.g., -24V), the system is indicating a short circuit or an open loop in the sensor cabling.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Length Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IQS 450 is calibrated for a specific electrical length. Ensure that the sum of the transducer cable and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEA 402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eextension cable exactly matches the system length (TSL) marked on the conditioner label.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit is designed for 35 mm DIN-rail mounting. It should be installed in a protected junction box (such as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJB 118\u003c\/strong\u003e) as close to the machine as practical while remaining within the specified temperature limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent EMI from polluting the vibration signal, terminate the cable shields at the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS 450\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eend. Ensure the aluminum housing is securely clipped to the DIN rail, which should be connected to a clean instrument ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS 450 (204-450-000-001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis distinguished by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExceptional Linearity\u003c\/strong\u003e. In critical machinery protection, precision is paramount for identifying early signs of shaft instability. The IQS 450 provides a clean, high-bandwidth signal that allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem to extract sub-harmonic vibration data and perform advanced diagnostics like shaft centerline plots. Its rugged Swiss design ensures a stable \"Zero Point\" over years of operation, minimizing the risk of drift-induced false trips.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695203873131,"sku":"IQS450 204-450-000-001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-iqs450-204-450-000-001-signal-conditioner-sypjz041zup_47a5c829-547d-48be-94e5-8cb7109d7a56.jpg?v=1766130606","url":"https:\/\/www.plcprotech.com\/fr\/products\/vibro-meter-iqs450-204-450-000-001-signal-conditioner","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}